Materials Required; Sanitizing Procedure - SHURflo HeavyDuty Advantage BIB 94-360-05 Manual

Beverage gas pump
Table of Contents

Advertisement

PUMP SANITIZING
The SHURflo Juice pump is only one piece of a beverage dispensing system. Therefore, frequent sanitization
of the pump and ALL equipment in the system is required. Sanitization is dependent on the concentrate
type and its' manufacturers requirements. Factors which also affect the frequency of this procedure are,
temperature, facility conditions, installation, and equipment.
instructions for their sanitizing requirements. Perform the following procedure to assure compliance with NSF
listed sanitizing requirements for the SHURflo Juice pump (only). Ref.: SHURflo Service Bulletin

MATERIALS REQUIRED:

• Common household bleach (Sodium Hypochlorite; 5.25%) or equivalent.
• Common household non-sudsing liquid detergent, suitable for use in a automatic dish washing machine.
• An adapter is needed to hold the bag connector on the syrup inlet (suction) line open. A fitting cut
from an empty B-I-B will serve as the adapter.
• A 6 ft.
length of
[2 M]
• Two five gallon buckets
• Measuring cup

SANITIZING PROCEDURE

1. Turn
CO
pressure to the pump. Open the dispenser valve to drop the line (outlet) pressure.
OFF
2
a) Remove the liquid outlet fitting from the pump. Install the bypass tube fitting in the outlet port of
the pump and screw in place.
b) Immerse the bag connector and inlet suction tubing in 2 gallons
).
[48-82°C]
2. Turn ON CO
to the pump (approx. 20 psi.
2
the pump to flush out concentrate residue. Turn OFF CO
3. Prepare 1 gallon
[3.8 L]
detergent per each gallon of warm water.
a) Place the bag connector in the detergent solution
b) Pump approximately
c) Turn
CO
pressure to the pump. Allow the detergent solution to remain in the pump for a
OFF
2
contact time of two minutes.
d) Turn the pump upside down and operate the pump until the remaining detergent solution is
pumped out. Turn
4. Repeat steps; 1b) and 2 (i.e.: flush with 2 gallons of warm water.)
5. Prepare 1 gallon
[3.8 L]
of bleach per each gallon of water to obtain a mixture of 100 ppm.
[7.5 cc]
a) Place the bag connector in sanitizing solution container.
b) Pump approximately
c) Turn
CO
pressure to the pump. Allow the sanitizing solution to remain in the pump for a
OFF
2
contact time of two minutes.
d) Turn the pump upside down and operate the pump until the remaining sanitizing solution is
pumped out. Turn
6. PRODUCT PURGE: Connect bag connector to the concentrate B-I-B. Operate the pump until a
steady stream of concentrate flows through the bypass tubing. Pump approximately 10 oz.
concentrate through the pump. Turn
7. Disconnect the bypass tubing and reinstall the concentrate line to the dispenser. Reset pump to the
original CO
pressure. Test the dispensing valve for proper operation. Sample the dispensed drink
2
for proper brix and to assure that there is no off-taste.
concentrate purging may be necessary.
WINTERIZING
tubing with a SHURflo output fitting. (To serve as the bypass hose)
1
/
[6 mm]
4 "
[19L]
of detergent solution in a clean container. Mix at the ratio of 1 oz.
gallon
of detergent solution through the pump.
3
/
[2.8 L]
4
CO
pressure.
OFF
2
of sanitizing solution (Hypochlorite) in a clean container. Mix at the ratio
gallon of sanitizing solution through the pump.
3
/
4
CO
pressure.
OFF
2
CO
OFF
Consult other equipment manufacturer's
), and pump the 2 gallons of warm water through
[1.4 bar]
pressure to the pump.
2
pressure.
2
If an off-taste is detected additional
Page: 4 of 6
#
1025
of warm water (120-180°F
[7.5L]
of
[30 cc]
oz
1
/
4
of
[300 cc]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents