Faultfinding

In the event of an accident or malfunction, immediately disconnect
the spark plug connector (
Problem
Power generator
does not start
Power generator
has too low
or no
voltage
18
Possible cause
Oil shutdown mechanism
responds
Spark plug covered in soot
No petrol
Defective motor
Controller or condenser
defective
Overcurrent circuit-breaker
triggered
Air filter dirty
 29) from the spark plug (
Troubleshooting
Check oil level, replenish engine oil
Clean or replace spark plug.
Electrode spacing 0.6 mm
Refill with petrol
Repair by Service Centre
Repair by Service Centre
Press switch and reduce consumer
output
Clean or replace filter
 30).