Side View - Raypak 185A Replacement Instructions Manual

Pc board, temperature control & sensor
Hide thumbs Also See for 185A:
Table of Contents

Advertisement

PLASTIC SHIELD &
BRACKET INSTALLATION
Make sure the power and gas are off.
1. Note that the plastic shield is installed under
the front bracket as pictured. Install the
shield brackets and plastic shield using the
existing screws (#8 x ½") and included
washers on the control panel bracket as
shown in Fig. 19.
2. Connect the wire harnesses to the board.
(Note the location of the clear plastic strip
with the thin connector. This is sometimes
disconnected when there is a remote con-
trol in the system. Refer to the remote wiring
instructions for further details.) Make sure
3-wire sensor P1 is connected.
3. Install the plastic shield over the board and
attach to the brackets using the two black
#10 X ½" screws and washers provided in
the kit. See Fig. 20 and Fig. 21.
4. Go to remote operation instructions.
OR
Return the control panel bracket to the up-
right position and re-attach using the screws
previously removed.
BRACKETS
2 PLACES
Fig. 21
Page 9
241169
P/N
Effective: 10-01-10
Replaces: 09-05-08
SHIELD
BRACKETS
CLEAR PLASTIC STRIP
WITH THIN CONNECTOR

SIDE VIEW

Rev 4
Fig. 19
Fig. 20