Status Codes; Program Modes; Fault Codes - Raypak 185A Replacement Instructions Manual

Pc board, temperature control & sensor
Hide thumbs Also See for 185A:
Table of Contents

Advertisement

NOTE: The LCD temperature display may not agree with the temperature reading of your pool or spa thermometer. The
heater reads the water temperature at the inlet. Due to the circulation characteristics of any pool or spa, the water tem-
perature at the inlet to the heater may differ from that observed at a given location in the pool or spa.
DIAGNOSTICS
The digital thermostat models are equipped with on-board
diagnostic controls. If there is a safety fault, a fault code will
be displayed along with a service indication.
If the PRS fault code is displayed, it indicates that there is
insufficient water flow through the heater. Make sure the
pool filter and pump strainer are clean before calling a serv-
ice representative.

STATUS CODES

Display
Definition
CFH
Call for heat
CLK
Time clock
EOL
End of line test (Factory Use Only)
LON
Low NOx Unit
OFF
Off mode
PRO
Propane gas configured
REM
Remote control activated
SPK
Spark
SPR
Spare fault code indicator

FAULT CODES

Display
Definition
BD1
Board failure
EEP
Microprocessor error
FAN
Blower pressure failure
FFL
Flame sensing when pilot and gas valves are
closed
GVC
Gas valve closed
GVO
Gas valve open
HL1
High limit switch #1 open
HL2
High limit switch #2 open
IGN
Ignition failure
ILO
Ignition lockout - Propane units only
PRS
Water pressure switch open
ROL
Heat roll-out safety switch open
SNS
Sensor failure, Water temp. below 36°F or
above 110°F
VNT
Vent switch open - This is jumped from the fac-
tory.
Page 13
READING A FAULT
The word "SERVICE" will flash on and off if the PC board de-
tects a known fault. The fault will be displayed in three big
letters on the lower left of the display.
3 Letter
Fault Code
See table
for fault def-
inition

PROGRAM MODES

Display
Definition
CCC
Celsius setting
F/C
Change from Fahrenheit to Celsius
FFF
Fahrenheit setting
RES
Reset defaults
SET
Set point max adjustment
241169
P/N
Rev 4
Effective: 10-01-10
Replaces: 09-05-08
Service Will
Flash

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

265a335a405a

Table of Contents