Remote Control Wiring - Raypak 185A Replacement Instructions Manual

Pc board, temperature control & sensor
Hide thumbs Also See for 185A:
Table of Contents

Advertisement

REMOTE CONTROL WIRING

Important Installation Notes for Remote or External Wiring Configuration
Remote wiring must be run in a separate conduit.
Remote wiring must not be run parallel to high voltage lines.
For runs of under 30 feet, remote wiring should have stranded conductors with a minimum of 22 AWG, 600V, cable
twisting 1.5 to 2.5 in. lay and jacketed.
For runs over 30 feet, the conductors should be a minimum of 20 AWG, 600V, cable twisting 1.5 to 2.5 inch lay that is
shielded and jacketed.
Maximum cable length is 200 feet.
For both two- and three-wire remote systems, the provided 7-pin wiring connector must be utilized. Please refer to the
wiring instructions.
NOTE: The remote wires must be connected to the 7-pin connector before the connector
is plugged into the board.
2-Wire Remote Control (On-Off)
This application assumes that only one heating function (pool or spa) is required.
Wire Nut - BLK/ORN
To Pool (COMM)
ORN/BLK - To Spa (COMM)
BLU - 24VAC
P8 Connector
3-Wire Remote Control Using Three-Position Switch (Pool-Off-Spa, or Low-Off-High)
This application assumes that both heating functions (pool and spa) are required.
BLK/ORN - To Pool (COMM)
ORN/BLK - To Spa (COMM)
BLU - 24VAC
P8 Connector
Page 15
1. Turn on power to the heater.
2. For a 2-Wire Remote Control from a remote without its own sen-
sor, push the mode button to the "POOL" or "SPA" mode and set
the desired setpoint (eg. 102 °F for spa).
3. For a 2-Wire Remote Control from a remote with its own sensor,
push the mode button "POOL" or "SPA" mode and set the tem-
perature to the highest setting available on the control. The actual
setpoint will be controlled by the remote control.
4. Turn the mode button to "OFF" and remove power from the heater.
5. On the "Remote Interface Harness", connect the BLUE wire to one
side of the "REMOTE" switch and connect the other side to either
the ORANGE/BLACK wire for "SPA" operation or the BLACK/OR-
ANGE wire for "POOL" operation.
6. Attach wire nut on unused wire to the "Remote Interface Harness."
7. Install the "7-Pin Remote Interface Harness" to the P8 connector
and turn power "On" to the heater.
See instructions on previous page to activate the remote control.
1. Turn on power to the heater.
2. Push the mode button to the "POOL" or "SPA" mode and set the
desired temperature for each (eg. 80°F for Pool and 102°F for
Spa).
3. Turn the mode button to "OFF" and remove power from the heater.
4. On the "Remote Interface Harness" connect the BLUE wire to one
side of the "REMOTE" switch and connect the ORANGE/BLACK
wire for "SPA" operation and the BLACK/ORANGE wire for the
"POOL" operation.
5. Install the "Remote Interface Harness" to the P8 connector and
turn power "ON" to the heater.
See instructions on previous page to activate the remote control.
241169
P/N
Rev 4
Effective: 10-01-10
Replaces: 09-05-08