Exercise: Edit Mode – Modify program P10
1. Select the program P 10 – SEAM 10 Manuel and press
2. Select segment 1.
3. Modify the following parameter settings:
Segment 1:
stitch length 6 mm
sewing foot stroke 2.5 mm
thread tension 30
stitch count : mode 1 (count stitches), number of stitches 10
Segment End Mode : Stop active On, Thread trim inactive Off, Needle Up inactive Off, Foot lifted inactive Off
start backtack: inactive Off
end backtack: inactive Off
Foot lifted: when sewing stops on the seam: inactive Off
Segment 2:
stitch length 3 mm
sewing foot stroke 5 mm
stitch count: mode 0 (not counted)
Segment End Mode: Stop active On, Thread trim active On, Needle Up active On, Foot lifted active On
start backtack: inactive Off
end backtack: active On
Global parameters of program:
name of the program: TEST TRAINING
FabricThickness: active On
Sewing foot stroke: Mode 2.Value On/Off, Min. Material thickness: 3 mm
stitch lengths: Mode linear, Stitch Length 6mm, Min. Material thickness: 2 mm, Max.Material thickness: 5 mm