Exercise: Sewing in Manual Mode, Gap and Gap+
Pre-setting in Manual Mode
• modify the base parameters :
• stitch length 3.8 mm
• thread tension 25%
• sewing foot pressure 5
• sewing foot stroke 3 mm
• modify the other parameters P...
• Thread trimmer active (On)
• Backtack at seam begin active (On)
• Number of stitches backward (3 points)
• Number of stitches forward (3 points)
• Stich length default active (On)
• End backtack active (On)
• Number of backward stitches (3 points)
• Number of forward stitches(3 points)
• Stich length default active (On)
• Gap (edge guide): 10 mm
• adjust the additional values:
• 2
nd
stitch length 6.0 mm
• 2
nd
thread tension 30%
nd
• 2
gap (edge guide distance) 20 mm
During Sewing Process
• start sewing
(automatic start backtack)
• activate/deactivate the additional values
activate 2
nd
stitch length
• activate 2
nd
foot stroke
• activate 2
nd
thread tension
• activate 2
nd
gap (gap+)
• deactivate the secondary values
• stop sewing, end of seam (pedal -2)
(automatic end backtack)