Power Supply Specifications; Troubleshooting - GE Tetra GEPS24-100U-NA Installation Manual

Led systems power supply, 120-277 vac input/24 vdc output/100w, 24 volt

Advertisement

Power Supply Specifications

Performance Data
Input Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
THD
PF
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Environmental Rating
Dimensions

Troubleshooting

Symptom
Solution
All letters are OFF
• Recycle AC power, turn it off, then turn on again.
• If still off, check the power supply DC output voltage using a voltmeter. It should be nominally
Some LEDs appear dim
• Ensure the overall length of the Tetra
• Ensure the length of supply wire is equal to or below the recommended remote mounting distance.
Some of the letters
• Inspect and correct the wires of the non-illuminated letters for damage/polarity issues; If no issues are found, see the
are not illuminated
Shadows
• Re-route supply wire and secure to the back of the can with electrical grade RTV silicone. Adjust wire connector
• Adjust LED layout to ensure uniformity of illumination of the face of the letter.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
This Class [A] RFLD complies with the Canadian standard ICES-005. Ce DEFR de la classe [A] est conforme à la NMB-005 du Canada.
This product is intended to be used as a lamp control gear that is installed after the mains control switch.
For the most up-to-date version of this installation guide, please visit https://products.currentbyge.com/sign-lighting
» If there is DC output, inspect and correct all DC wire damage/polarity issues; If no issue is found, replace the
OFF-module string.
» If there is no DC output, have a licensed electrician check the input AC voltage and if there is correct AC voltage,
replace the power supply.
» If there is no AC voltage, correct the upstream AC issue.
troubleshooting solution for "All letters are OFF."
orientation so that it does not cover any LEDs.
Conforms to the following standards:
GE and the GE Monogram are trademarks of the General Electric Company and are used under license. Information provided is subject to
change without notice. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or
guarantee, express or implied, that such performance will be obtained under end-use conditions. © 2019 GE Current, a Daintree company.
www.LED.com
SIGN111 (Rev 10/24/19)
Min
108
-
0.35
-
0.9
23.0
-
-
-40°C
0%
-40°C
IP66 rated: must be protected from direct exposure to the weather
9.5 in. x 1.7 in. x 1.2 in. (240 mm x 43 mm x 30 mm)
LED System does not exceed the maximum load.
®
GE2021-0922
Typical
120-277
50/60
-
-
-
24.0
-
-
+25°C
+55°C*
-
-
*Maximum case temperature is
V.
24
Max
305
-
1.1
20
-
25.0
4.0
96
95%
+85°C
°C
85