Download Print this page

Power Supply Specifications - GE Tetra GEPS12-60 Installation Manual

Led systems power supply, 12 volt

Advertisement

NOTE: When installing power supply, connect to the appropriate sized building breaker or disconnect device for line and neutral
connections, in accordance with local, state or country regulations.
NOTE: The grounding and bonding of the power supply and overall sign shall be done in accordance with National Electric Code (NEC)
Article 600.

Power Supply Specifications

Performance Data
Input Voltage (VAC)
Input Frequency (Hz)
Input Current (A)
Output Voltage (VDC)
Output Current (ADC)
Output Power (W)
Dimensions
Environmental Specifications
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Load per Power Supply
Tetra miniMAX
GEWHMMTS8, GEWWMMTS8
GEWHMMS6, GEWWMMS6
GEBLMMS5, GEGLMMS5, GERDMMS5
Tetra MAX
GEWHMXTS6, GEWWMXTS6
GEWHMHTS6, GEWWMHTS6
GEWHMXWA5, GEWWMXWA5, GEBLMXWA5,
GEGLMXWA5, GERDMXWA5
GERCMXWA6, GEYGMXS6
GERCMXWL6
GERDMXWL6
Tetra PowerMAX
GEWHPMTL5, GEWWPMTL5
GEWHPMS2-65K, GEWWPMS2-30K
Tetra PowerStrip
GEWHSSP3-65K, GEWWSSP3-41K
Maximum Remote Mounting Distance
Tetra miniMAX
Tetra MAX
Tetra PowerMAX
GEWHPMTL5, GEWWPMTL5
GEWHPMS2-65K,
GEWWPMS2-30K
Tetra PowerStrip
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.
© 2011 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
GEPS12-60
Min
Typical
90
100-240
-
50/60
-
-
11.4
12.0
0.8
-
-
-
9.5 in. x 1.7 in. x 1.2 in. (240 mm x 43 mm x 30 mm)
18 AWG
(0.82 mm
)
2
30 ft./9.1 m
30 ft./9.1 m
30 ft./9.1 m
15 ft./4.5 m
30 ft./9.1 m
Conforms to the following standards:
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
Max
Min
264
108
-
-
0.85
-
12.6
11.5
5.0
0.8
60
-
Min
-40°C
-
-40°C
Min
3 modules/1.2 ft. (0.37 m)
3 modules/1 ft. (0.30 m)
3 modules/1.2 ft. (0.37 m)
2 modules/1 ft. (0.30 m)
2 modules/1 ft. (0.30 m)
3 modules/1.2 ft. (0.37 m)
3 modules/1 ft. (0.30 m)
2 modules/1 ft. (0.30 m)
2 modules/1 ft. (0.30 m)
2 modules/1.3 ft. (0.41 m)
2 modules/1 ft. (0.30 m)
1 module/1 ft. (0.30 m)
16 AWG
14 AWG
(1.31 mm
)
(2.08 mm
)
2
2
50 ft./15.2 m
80 ft./24.4 m
50 ft./15.2 m
80 ft./24.4 m
50 ft./15.2 m
80 ft./24.4 m
20 ft./6.1 m
30 ft./9.1 m
25 ft./7.6 m
35 ft./10.6 m
GEPS12-60U
Typical
120-277
50/60
-
12.0
-
-
Typical
+25°C
-
-
*Maximum case temperature is 90°C
150 modules/60 ft. (18.29 m)
120 modules/40 ft. (12.20 m)
90 modules/36 ft. (10.97 m)
120 modules/60 ft. (18.29 m)
80 modules/40 ft. (12.20 m)
135 modules/54 ft. (16.46 m)
162 modules/54 ft. (16.46 m)
160 modules/80 ft. (24.38 m)
140 modules/70 ft. (21.34 m)
38 modules/25 ft. (7.62 m)
50 modules/25 ft. (7.62 m)
16 modules/16 ft. (4.88 m)
12 AWG
10 AWG
(3.31 mm
)
(5.27 mm
)
2
2
120 ft./36.6 m
-
120 ft./36.6 m
-
120 ft./36.6 m
-
60 ft./18.2 m
-
40 ft./12.1 m
75 ft./22.8 m
SIGN098-R092911
Max
305
-
0.61
12.5
5.0
60
Max
+65°C*
95%
+85°C
Max
8 AWG
(8.35 mm
)
2
-
-
-
-
100 ft./30.5 m

Advertisement

loading

This manual is also suitable for:

Tetra geps12-60u