Download Print this page
GE Tetra GEPS24-180U Installation Manual

GE Tetra GEPS24-180U Installation Manual

Led systems power supply, 24 volt

Advertisement

Quick Links

GE
Lighting Solutions
Tetra
LED Systems Power Supply
®
(GEPS24-180U)

Power Supply Features

• Supports Tetra PowerStrip DS, Tetra Contour
and Tetra Contour LS LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV equivalent)
• Damp location rated
• IP66 rated: separate enclosure required

BEFORE YOU BEGIN

Read these instructions completely and carefully.
Risk of electrical shock. Disconnect power before servicing or installing product. Risk of fire. Do not interconnect output terminations.
Risque de choc électrique. Couper l'alimentation avant le dépannage ou avant l'installation du produit. Risque du feu. Risques
d'incendie ou de choc lectriques. Ne pas interconnecter les bornes de sortie.

Power Supply Installation

1
Mount power supply and
remove junction box cover.
Carefully remove knockout
for AC line input wires. Install
appropriate electrical fittings
in the knockout holes for
wire protection.
imagination at work
WARNING/AVERTISSMENT
To Tetra LED System
Output wires
2
Connect the supply wire
that is attached to the Tetra
LED System to the red (+)
and black (-) output wires
of the power supply as
outlined in the "Electrical
Connections" section
of your LED system's
Installation Instructions.

Installation Guide

Green with
yellow
stripe
(ground)
White (neutral)
Black (line)
3
Connect the AC line to
the black (line) and white
(neutral) input wires of
the power supply using
18-14 AWG (0.82-2.08 mm
twist-on wire connectors.
Ground power supply by
connecting green wire with
yellow stripe to grounding
screw. Replace junction box
cover.
24
Volt
AC line
)
2

Advertisement

loading

Summary of Contents for GE Tetra GEPS24-180U

  • Page 1: Installation Guide

    Installation Guide Lighting Solutions Volt Tetra LED Systems Power Supply ® (GEPS24-180U) Power Supply Features • Supports Tetra PowerStrip DS, Tetra Contour and Tetra Contour LS LED lighting systems • Class 2 wiring per NEC Article 725 (SELV equivalent) • Damp location rated •...
  • Page 2: Power Supply Specifications

    1 - 8 8 8 - 6 9 - 4 3 - 5 3 3 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Tetra is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.