Installer
To assure you install this model easily and correctly, PLEASE
READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING
THE INSTALLATION. CHECK YOUR INSTALLATION FOR
COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER
APPLICABLE CODES. After installation, leave these instruc-
tions inside the fountain for future reference.
IMPORTANT
IMPORTANT! INSTALLER PLEASE NOTE.
97715C (Rev. B - 5/04)

Advertisement

loading

Summary of Contents for Halsey Taylor HRFG-EBP

  • Page 1 Halsey Taylor Owners Manual Non-Refrigerated Marblyte Fountain with Back Panel Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instruc- tions inside the fountain for future reference.
  • Page 2: Finished Floor

    HRFG-EBP, HRFG-SBP ROUGH-IN MARBLYTE BACK PANEL DETAIL 1 FINISHED FLOOR...
  • Page 3 INSTALLATION INSTRUCTIONS MARBLYTE BACK PANEL Care and Maintenance of Halsey Taylor Marblyte Fountains 97715C (Rev. B - 5/04)
  • Page 4 HRFG-EBP, HRFG-SBP ROUGH-IN STAINLESS STEEL BACK PANEL FINISHED FLOOR (BLOCKING & WALL SUPPORT IS REQUIRED IN THESE AREA FOR PROPER SUPPORT OF FOUNTAINS)
  • Page 5 INSTALLATION INSTRUCTIONS STAINLESS STEEL BACK PANEL Wall should already be framed for the fountain Attach wall plate assembly to wall Install back panel. Install rough-in plumbing Remove bottom access panel Remove elbow from end of p-trap Make water supply connections DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
  • Page 6 TOP VIEW 97715C (Rev. B - 5/04)
  • Page 7 3/8" O.D. UNPLATED 1/4" O.D. TUBE COPPER TUBE CONNECT WATER INLET COLD WATER SUPPLY BUILDING WATER INLET TO COOLER NOTE: WATER FLOW DIRECTION SERVICE STOP (NOT FURNISHED) TUBE IS PUSH IN COLLET SIMPLY PUSH IN SECURED TO RELEASE TUBE TUBE TO ATTACH IN POSITION PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO...
  • Page 8: Troubleshooting And Maintenance

    TROUBLE SHOOTING & MAINTENANCE Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8" diameter or small diameter wire. file or cut orifice material. If orifice is free of material deposits, regulate flow as in instructions on page 3(Step 7) or page 5(Step 9).