Installation And Initial Startup - FSP Technology EP 1500 Quick Manual

Line interactive ups
Hide thumbs Also See for EP 1500:
Table of Contents

Advertisement

3. Installation and Initial Startup

Before installation, please inspect the unit and contents that nothing is
damaged or missing.
Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. Please
place the UPS away from other units at least 20 cm to avoid interference. Do NOT operate the UPS
where the temperature and humidity is above the recommended limit (Please check the specs)
Connect to Mains and Charging
Plug in the AC input cord to the wall outlet and charge the UPS for
at least 6 hours before using. The unit charges its battery while
connected to the mains.
Connect Devices
Plug in the devices to the output connections on the rear panel of the UPS. Turn the power on by
pressing the switch, the devices are now protected by the UPS.
Connect Modem/Phone/Network for Surge Protection
(Only for the model with RJ-45)
Plug the modem/phone line into the surge-protected "IN"
connection on the rear of the UPS unit, the other end should be plugged into the "OUT"
connection on the computer for the phone.
Connect Communication Cable (Only for the model with USB/RS-232 port)
To enable remote UPS shutdown/start-up and status monitoring, connect the communication
cable from the USB/RS-232 port and the other to the communication port of your PC. With the
monitoring software installed, you can schedule UPS shutdown/start-up and monitor the UPS
status.
Turn On/Off the Unit
Press the switch to turn on the UPS. To turn off, press and hold the switch for 5 seconds.
6 hours
2
4. Important Safety Warning (PLEASE READ THE INSTRUCTIONS)
CAUTION!
To prevent the risk of fire or electric shock, use only indoors in a temperature and humidity
controlled area free of conductive contaminants. (See the specifications for)
To reduce risk of overheating, do not cover the UPS' cooling vents and avoid exposing the unit
to direct sunlight or installing the unit near appliances such as heaters or fires.
Do not attach non-computer items, such as medical equipment, life-support equipment,
microwave ovens, or vacuum cleaners to UPS.
Do not plug the UPS input into its own output.
Do not place beverages or any other items containing liquid on or near the unit.
In the event of an emergency, press the OFF button and disconnect the power cord from the
AC power supply to properly disable the UPS.
Do not attach a power strip or surge suppressor to the UPS.
If the UPS has a metal chassis, for safety purpose, grounding is a must during installation in
order to reduce leakage current below 3.5mA.
Repair or service work should be performed or supervised by trained personnel only.
When replacing the batteries, use the same number and type.
Internal battery voltage is 12VDC. Sealed, lead-acid, 6-cell battery.
Do not dispose of batteries in a fire as they may explode.
Do not open or damage the battery or batteries. Released electrolyte is harmful to the skin
and eyes.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
A battery can present a risk of electric shock and high short circuit current. The following
precautions should be observed before replacing batteries:
1)
Remove watches, rings, or other metal objects.
2)
Use tools with insulated handles.
3)
Wear rubber gloves and boots.
4)
Do not lay tools or metal parts on top of batteries.
5)
Disconnect charging source prior to connecting or disconnecting batter terminals.
Attention: Hazard through electric shock. Risk when disconnecting the unit from the mains, the
battery may still contain voltage. The battery should be correctly disconnected at the plus and
minus pole of the connectors on the battery when maintenance work inside the UPS is carried out.
5. Software Download & Installation (Only for the model with
communication port)
Please follow steps below to install software:
1. Please visit http://www.power-software-download.com
2. Click ViewPower software icon and choose your required language to download.
3. Follow the on-screen instructions to install the software.
4. When your computer restarts, the monitoring software will appear as an orange "plug" icon at
the bottom right of your screen (system tray) where the clock is.
5. User name and password in software management:
User name: administrator
Password: administrator
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ep 2000

Table of Contents