Communication Ports On Ifd9503 - Delta IFD9503 Applications Manual

Canopen slave communication module
Table of Contents

Advertisement

PIN 8
Off
Off
On
On
On
On
Note:
The changed setting of the baud rate of CANopen is only valid when IFD9503 is re-powered. When
IFD9503 is operating, changing the baud rate will be invalid.
2.5

Communication Ports on IFD9503

The communication ports on IFD9503 are used for the connection the
equipment (Delta programmable logic controller, Delta AC motor drive,
Delta temperature controller, Delta servo drive, Delta human machine
interface and custom equipment).
1. PORT 1 PIN definition:
PORT 1 sketch
Note:
PORT 1 supports RS-485 communication only.
2. PORT 2 PIN definition:
PORT2 sketch
DB9 male
Note:
PORT 2 supports RS-232 and RS-485 communication only.
DVP-PLC Application Manual
CANopen Slave Communication Module IFD9503
PIN 7
PIN 6
On
Off
On
On
Off
Off
Off
On
On
Off
On
On
6
5
4
3
2
1
PORT1
1
6
2
7
3
8
4
9
5
Baud rate
50k bps
125k bps
250k bps
500k bps
800k bps
1M bps
PIN
1
2
3
4
5
6
PIN
RS-232
1
N.C.
2
RXD
3
TXD
4
N.C.
5
GND
6
N.C.
7
N.C.
8
N.C.
9
N.C.
PORT2
PORT1
Description
N.C.
GND
DATA-
DATA+
N.C.
N.C.
RS-485
N.C.
N.C.
DATA-
N.C.
N.C.
N.C.
N.C.
DATA+
N.C.
7

Advertisement

Table of Contents
loading

Table of Contents