Siemens SIMODRIVE 611U Product Information page 57

Connecting to the technology cpu
Table of Contents

Advertisement

Load the program into the technology CPU and switch to RUN
Save and compile the technological settings.
The mode selector switch of the technology CPU is still at the STOP position.
Use Technology > Connect with the target system to establish the connection to the
technology CPU.
Use Technology > Load into the target system to load the project into the technology CPU.
Once the project has been loaded into the target system, use the mode selector switch to
switch the technology CPU to RUN.
Creating the technology DBs (TO-DBs)
Once the configuration with S7T Config has been completed, technology DBs must be
produced for the created technology objects (e.g. axes, cams, output cams, measuring
inputs). The "Technology Object Management" is used here.
Switch to the "Technology Object Management" if it is not yet open. Otherwise, double-click
on the Technology objects entry in the Technology folder of the SIMATIC station to start the
"Technology Object Management".
Figure 4-38
Connecting the SIMODRIVE 611U to the Technology CPU
Product Information, 03/2008, A5E00272066-05
Start TOM from the SIMATIC Manager
Commissioning
4.4 Setting up a STEP 7 project
57