When Connecting S-2416 Units To One Another - Roland Digital Snake S-2416 Owner's Manual

Stage unit
Table of Contents

Advertisement

Connecting REAC Devices

When Connecting S-2416 Units to One Another

NOTE
Change the setting of the [REAC MODE] switch and [MODE] switch while the S-2416 is powered down.
Slave-unit settings
[REAC MODE] switch
[MODE] switch
1
REAC SLAVE MODE
2
REAC BACKUP MODE
6
AES/EBU OUTPUT
Audio signals input via INPUT 17 through 24 on the master unit are
output from AES/EBU OUTPUT on the slave unit.
16
S-2416: Slave
Setting
S (Slave)
Setting
OFF
CLOCK SLAVE
OFF
BACKUP
ON
17-24
S-2416: Master
Master-unit settings
[REAC MODE] switch
[MODE] switch
2
REAC BACKUP MODE
6
AES/EBU OUTPUT
Audio signals input via INPUT 17 through 24 on the slave unit are
output from AES/EBU OUTPUT on the master unit.
Setting
M (Master)
Setting
OFF
BACKUP
ON
17-24

Advertisement

Table of Contents
loading

Table of Contents