APPENDIX B. SETUP CONFIGURATION
In order to configure the MIUXXX/485 to remote RTU, Meter or Scada terminals the
following setup is required for 2w or 4w (RS485) networks
See Fig ONE for MIUXXXX/485 layout and dip switch setting
Switch
Three
Switch Three Setting
SW - One
On
SW - Two
Off
SW - Three Off
SW - Four Off
Switch One Setting
SW - One
SW - Two
SW - Three Off
SW - Four Off
Final Factory Configuration (MIUXXXX/485) for PEXXX modem module
No, Power saving modes, No Auto Reset mode
Switch two ON Switch one, three and four are OFF.
MIU S3 (external)
SW-2 Closed (ON) MIU is configured for DB9 interface to
SW-1, -3 & -4 Open (OFF)
CIU Installation, Operation & Diagnostics
Jumper 7
Pin 1
3&4
Switch
One
J2 Pin1
Off
Jumper
On
3 & 4
5 & 6
7 & 8
13 & 15
Modem interface connection.
Edition: June 17, 2003
Power
Plug
RJ11
Telco
DB9 (RS232)
Configuration
only
DB 9 Connection
1 Carrier Detect
2 Received Data
3 Transmit Data
4 DTR
5 Signal Ground
J 8
6 DSR
Pin 1
7 RTS
2 & 3
8 CTS
9 Ring Indicator
Page C-1