Telect MIX 56 User Manual page 99

Telect user manual ethernet connector
Table of Contents

Advertisement

MIX 56 User Manual
122188-10 A0
Telect, Inc.
7.
Tab to the "RAI" field and toggle between the available options by
pressing the spacebar and then pressing Enter. This field only ap-
plies to a T1 signal and selects the remote alarm format (remote
alarm indication, RAI). The available options are bit2 equals zero
in every channel (Bit 2=0) and FS bit of frame 12 of the framed sig-
nal (FS Bit).
This field is only available in the "T1/E1 Test on High Speed Line"
mode.
8.
To apply the BER test selected, tab to the [Apply] button and press
enter. A prompt will appear telling you that this action will cause a
continuous traffic interruption and ask if you want to continue.
If a Low Speed Channel is selected that is either disabled or un-
available, then the [Apply] button is not enabled.
9.
Type "y" and Enter to perform the selected BER test.
4 Software Operation
NOTE
4-53

Advertisement

Table of Contents
loading

Table of Contents