LG Therma V Series Installation Manual page 55

Air-to-water heat pump
Hide thumbs Also See for Therma V Series:
Table of Contents

Advertisement

Terminal Block Information (3Ø Electric Heater)
Symbols used below pictures are as follows :
- L, L1, L2 : Live (230V AC)
- N : Neutral (230V AC)
- BR : Brown , WH : White , BL : Blue , BK : Black
Terminal Block 1
energizing water
pump for solar
thermal system
3WAY VALVE
(B)
1
2
3
L
L1
N
BR
WH
BL
water flow switching between using
solar thermal heating and skipping
solar thermal heating
Terminal Block 2
opening or closing
water flow for FCU
OUTDOOR UNIT
11
12
13
14
1(L)
(2(N)
3
L1
(BR)
BL
BK
BR
Power supply for Indoor
unit and communication
Terminal Block 3
connecting external electric
power supply for sanitary
water tank electric heater
EXTERNAL POWER
(W/TNK E/HEATER)
1
2
3
L
N
R
BR
BL
BR
connecting external electric
power supply for internal
water flow switching between
under floor heating and sanitary
water tank heating
WATER
WATER
3WAY VALVE
PUMP
TANK
(B)
HEATER
4
5
6
7
8
L
N
L
N
L
BR
BL
BR
BL
BR
turn on or off sanitary
water tank heater
cooling
THERMOSTAT
2WAY VALVE
(Default : 230V AC)
(A)
15
16
17
18
L2
N
L
N
WH
BL
BR
BL
Connection for thermostat
(230V AC)
Supporting type : Heating only or
Heating/Cooling
EXTERNAL POWER
(INTERNAL E/HEATER)
4
5
S
T
BK
GY
electric heater
Piping and Wiring for Indoor Unit
(A)
9
10
L1
N
WH
BL
19
20
L1
L2
WH
BK
Terminal
Block 1
Terminal
Block 2
Terminal
Block 3
Installation Manual 55