Sanitary Water Tank and Sanitary Water Tank Kit/Solar Thermal Kit

To establish sanitary water circuit, 3way valve and sanitary water tank kit is required. If solar thermal
system is pre-installed at the installation field, solar thermal kit is required to interface solar thermal
system – to – sanitary water tank – to –

General Information

supports following 3way valve.
Type
Power
SPDT
230V AC
3-wire
(1)
(1) : SPDT = Single Pole Double Throw. Three wires consist of Live1 (for selecting Flow A), Live 2
(for selecting Flow B), and Neutral (for common).
(2) : 'Flow A' means water flow from the indoor unit to under floor water circuit.
(3) : 'Flow B' means water flow from the indoor unit to sanitary water tank.
Operating Mode
Selecting " Flow A" between
" Flow A" and " Flow B" (2)
Selecting " Flow B" between
" Flow A" and " Flow B" (3)
Accessories Installation
Supported
Yes
Yes
Installation Manual 61