Download Print this page

Electrical System Maintenance - DEFYGRAVITY SHERCO 250-300 SE/R Manual

Advertisement

250-300 SE/R
Brakes (continued)
2

Electrical system maintenance

REMOVING THE BATTERY
2
122
1
1
3
Install the new pads.
Reinstall the retaining pins
Check the brake fluid level and fill if necessary.
(
p.114 et p. 116)
ATTENTION
Do not use the bike until the brake lever and the pedal
are operational. «Pump» the brake lever / brake pedal
up and down until the brake pads are in contact with
the discs.
Turn off all electric devices and stop the engine.
ATTENTION
- 250-300 SE (standard): Confirm that the key start is in
the OFF position.
- 250-300 SE/R (racing): Confirm that the on / off swit-
ch is in the OFF position.
Risk of damage to the CDI.
- Remove the seat (
- Remove the air filter (
- The battery is located at the bottom of the filter
housing.
- Remove the two screws
battery retaining bracket.
- Disconnect the negative cable from the battery
- Disconnect the battery positive cable
- Remove the battery from the top.
and clips
2
1
p.100)
p.100).
that retain the
1
.
3
.
2

Advertisement