REPLACING MIC CORD
Removing Cord from Mic Body
1.
Refer to illustration on next page. Grasp locking
collar and, while pushing it firmly towards mic
body, turn it counterclockwise ¼ turn to disengage
it from mic body.
2.
Disconnect cord from mic body by pulling TELCO
connector (which has no tab on it) out of TELCO
jack on circuit board inside mic body.
Installing Cord Into Mic Body
1.
Slide locking collar on mic end of cord away from
TELCO plug and past strain relief on cord.
2.
Orient TELCO plug on mic end of cord so that it
aligns with TELCO jack inside mic body and its
contacts face rear of mic housing.
3.
Pass TELCO plug through hole at bottom of mic
body and plug it into TELCO jack on circuit board
inside mic body.
4.
Slide locking collar back up on cord with tabs on
its sides facing sides of mic body.
5.
Push locking collar firmly into hole at bottom of
mic body then turn it ¼ turn clockwise to secure it
in place.