Download Print this page
Siemens MXL Series Installation And Wiring Instructions

Siemens MXL Series Installation And Wiring Instructions

Rack mount kits (rks) for acm-rk, mkb-rk, mmb-rk, mom-rk, mps-rk, sys-rk, tsp-rk, vsm-rk, cables-rk

Advertisement

Quick Links

Installation and Power Limited Wiring Instructions
Model MXL/MXLV Rack Mount Kits (RKs)
for ACM-RK, MKB-RK, MMB-RK, MOM-RK,
MPS-RK, SYS-RK, TSP-RK, VSM-RK, and Cables-RK
INTRODUCTION
Model RK series of panels and cables provides standard 19" rack mounting for MXL
The
(without Voice) and MXLV (with Voice) modules. Table 1 lists the individual rack mount kits along with
the specific modules that mount onto them.
RACK
MOUNT KIT
ACM-1, MMM-1, PIM-1,
ACM-RK
TBM-1, and TMM-1
MKB-3, PIM-1
MKB-RK
MMB-1 or PSR-1
MMB-RK
MOM-RK
Up to 3 MOM-4s, MOM-2s,
OMM-1s, and/or OMM-2s
MPS-RK
Up to 2 MPS-6/-Ws and/or
MPS-12/-Ws
SYS-RK
EL-410D
TSP-40
TSP-RK
Up to 6 VSM-1s, VLM-1s,
VSM-RK
VFM-1s, and/or VSB-1s
None
FILLER
PLATE*
4 special cables for
CABLES-RK
connecting modules
(Required)
* Filler plates can be purchased from any rack manufacturer.
NOTE: Each MXL/MXLV module that is mounted must be ordered separately.
Siemens Building Technologies, Inc.
8 Fernwood Road
Florham Park, New Jersey 07932
P/N 315-093402-9
TABLE 1
MXL/MXLV RACK MOUNT KITS
MOUNTS
MODULE(S)
PLACEMENT
PANEL HEIGHT
ON RACK
Front
17 1/2" X 19"
Front
12 1/4" X 19"
Rear
12 1/4" X 19"
Rear
17 1/2" X 19"
Rear
8 3/4" X 19"
Rear
8 3/8" X 19"
Front
12 1/4" X 19"
Front
Front
As required x 19"
Siemens Building Technologies, Ltd.
2 Kenview Boulevard
Brampton, Ontario L6T 5E4 CN
Fire Safety
TYPE OF
X WIDTH
SYSTEM
MXLV
MXL/MXLV
MXL/MXLV
MXL/MXLV
MXL/MXLV
MXLV
MXL/MXLV
7" X 19"
MXLV
MXL/MXLV
MXL/MXLV

Advertisement

loading

Summary of Contents for Siemens MXL Series

  • Page 1 (Required) * Filler plates can be purchased from any rack manufacturer. NOTE: Each MXL/MXLV module that is mounted must be ordered separately. Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932...
  • Page 2: Rack Hardware

    RACK HARDWARE The MXL/MXLV rack mounting panels mount on a standard 19" wide x 18" deep rack (See Figure 1). Table 1 lists the recommended locations (front or rear) for the rack mounted modules and the panel heights of the rack mount kits. The following rack is available for typical installa- tions (Refer to Figure 1): 26"...
  • Page 3 TBM-2 TMM-1 Figure 2 EXTENSION FROM EXISTING TO ANN-1 CABLES-RK KIT MMM-1 CABLE (MKB-RK) Rear View of the ACM-RK NEW CABLE FROM CABLES-RK KIT MMM-1 ACM-1 TO MMB-2 NEW CABLE FROM CABLES-RK KIT ACM-RK PIM-1 NOTE: When you select non-supervision for an switch S1 to set the network address of the annunciator, there must also be one and MKB-3.
  • Page 4 2. After installing the printer to the plate, mount the plate to the rack using hardware supplied with the rack. Refer to the SYSTEM ASSEMBLY section below and Figures 6 (with Voice) and 7 (without Voice), for the recommended location on the rack. 3.
  • Page 5: System Assembly

    Figure 5 SYS-RK Components SYSTEM ASSEMBLY 6. The MMB-RK must be mounted directly behind the ACM-RK. NOTE 7. The TSP-RK must be located within 24 Before installing the modules onto the rack, inches of the MMB-RK. access to field wiring connections must be 8.
  • Page 6 " 4 " 4 " 0 " 0 " 6 094883, for further information on power and To meet these requirements, two wire ducts are non-power limited wiring. mounted along the sides of the rack assembly, as shown in Figure 8. Remove the wire duct cover, NOTE: If power-limited wiring is not used within a route all non-power limited wiring through the rack mount system, then the following...
  • Page 7: System Wiring

    TABLE 6 WIRING ENTERING THE RACK ASSEMBLY Module Termination Non-Power Limited Wiring ALD-2 MOM-4 Wiring to the following MXL/MXLV module termi- ALD-2I MOM-4 nations shown in Table 5 is considered non- CMI-300 MOM-4 power limited. The wiring must enter and exit the CSM-4* MOM-4 rack assembly through the bottom of the rack and...
  • Page 8 12 1/4" 8 3/8" 17 1/2" 12" 7" 70" 17 1/2" 7" 9" 12 1/4" Figure 6 MXLV (with Voice ) Mounted on 19" Rack...
  • Page 9 12" 12 1/4" 12 1/4" 17 1/2" 70" 9" Figure 7 MXL (without Voice) Mounted on 19" Rack...
  • Page 10 Figure 8 Installing the Wiring Duct...
  • Page 12 Siemens Building Technologies, Inc. Siemens Building Technologies, Ltd. 8 Fernwood Road 2 Kenview Boulevard Florham Park, New Jersey 07932 Brampton, Ontario L6T 5E4 CN P/N 315-093402-9...

This manual is also suitable for:

Mxlv seriesMxl-rk1