4.2 Electrical installation

If the product is not powered using the POE option:
Terminal block [A] is the power input for K
-
First turn off the circuit breaker/disconnection switch concerned
-
Connect the power to terminal block [A] using a cable with a cross-section of 2.5 mm²,
-
stripped over 5 mm (
50/60 Hz).
Secure the two wires close to the 2-pin terminal block, using one of the clamping collars
-
provided.
Connect the IT network cable to the RJ45 socket.
-
If the product is powered using the POE option:
With POE option, K
-
There is therefore no terminal block [A] present on the K
Voltage supplied by the POE switch for the terminal if using the POE option:
-
IEEE 802.3af - 12.95 W - category 3
Connect the bell relay if necessary. To do this,
-
connect the contacts for terminal block [B] of
the relay (230 V
off the circuit breaker/disconnecting switch
concerned, then connect the cables onto the
terminal block (0.5 to 1.5 mm² max cross-
section, stripped over a length of 5 mm). Secure
the two wires closest to the 2-pin terminal
block, using one of the clamping collars
provided.
/
), onto the rear connector on the terminal (110-230 V
LIVE
NEUTRAL
[A]
[B]
P
is powered only by the Ethernet cable (terminal block [C]).
ELIO
RIO
50/60 Hz, 1 A
). First turn
AC
max
P
.
ELIO
RIO
[C]
P
ELIO
RIO
Clamping
collar
AC
terminal.
[B]