"S"
123456TmBaAcFlt
555555 6 + + 0
ECP
TmBaAcFlt
*
5 + + 0
"T"
Registration
MSG 1 Sent
"T"
Test Alarm Sent
"X"
Reset (Y/N)
Resetting!
"↑"
Registration
MSG 1 Sent
"↓"
Enter PIN #
Status Display – Zone Mode
The status of the 7835C can be viewed on the 7720P. The status
display includes zone input status, test terminal status, tamper status,
battery condition, charging voltage status, and radio fault status.
Status Display – ECP Mode
The status of the control firmware can be determined in this mode if
the 7835C has software version 1.20 or higher and you have a 7720P
programming tool.
Zone Mode Status Display Interpretation for "S" Command
123456 The numbers 1-6 represent the 6 zone inputs, and follow
ADEMCO High Speed Format codes:
1 New Event
2 New Opening
3 Restore
4 New Closing
5 Normal
ECP Mode Status Display Interpretation for "S" Command
ECP
*
Indicates you are connected to a control with updated
firmware. If not, do not use "Radio Only" mode with that
particular control (applies only to Vista-10SE Family, Vista-
20SE Family, and Vista-30PSE control panels).
Zone and ECP Mode Status Display Interpretation for "S" Command
Tamper status follows High Speed Format codes above.
Tm
Ba
Represents battery condition:
+
Battery voltage acceptable
Battery voltage below 11.5V ± 5%
V
Battery voltage going low has not yet been sent to the
central station (appears only briefly)
X
Battery not installed
Represents line voltage:
Ac
+
AC line voltage OK
AC line voltage bad & reported
V
AC line voltage bad, not reported (reporting window not expired)
^
AC voltage restored, not reported as restored
Flt
Represents Radio Faults:
0
Normal
5
No contact with AlarmNet (check antenna, connections)
9
Hardware failure; requires factory service
CRC
RAM/EEROM corruption.
reprogram. If this fault recurs, return radio for service.
Test Registration
Sends a test registration to the central station, reporting as "5555
5555 9." Functional for unregistered 7835C's only. Refer to section
5.
Test Alarm
Sends a Test alarm to AlarmNet. Functional for registered 7835C's
only.
Reset the 7835C.
This will be the display following the "X" command.
Answering "N" will return to normal mode. Answering "Y" will
reset the radio and display the following:
Registration
Registers a programmed 7835C with AlarmNet. Refer to section 5.
Replacement Registration
Used only when replacing an existing 7835C. Refer to section 5.
– 31 –
6 Previously Reported Event
@ Telco New Event
P Telco Previously Reported
p Telco Restored
Reset the radio and, if necessary,