If the installation is a known repair/replacement, you can skip the previous section by selecting the
[↓] command to initiate the replacement registration process, beginning with the PIN entry as
follows.
Alarm Will Be
Sent, OK Y/N
Enter PIN#
Registration
MSG1 Sent
Registration
MSG2 Sent
Registration
MSG3 Sent
Registration
Waiting for ACK
Registration
Successful!
Registration
Canceled!
Substitution
Rejected!
– 22 –
If the installer proceeds beyond this
point by answering "Y," a correct PIN
number must be supplied to complete
the registration. Any attempt at
registration at this point, whether
successful or unsuccessful, will result in
a radio substitution alarm being sent to
the CS. Answering "Y" allows the
installer to continue registration.
Answering "N" will abort the registration.
If "Y" was chosen, see the next section on
Replacement Radios for the remainder of
the process.
The installer must enter a 4 digit alpha
numeric PIN # that must be obtained by
having an authorized person call the
AlarmNet TAC (Technical Assistance
Center). The PIN should be entered,
followed by the enter key.
Three messages are sent, then the unit
waits for acknowledgement.
If the PIN is valid, the new 7835C will
register and the old unit will be
unregistered. A radio substitution alarm will
be sent to the central station by AlarmNet.
If at any point in the substitution process
the installer chooses not to register the
7835C, this is the displayed message.
If an invalid PIN was entered this is the
display message, and the registration
process will be aborted and will need to
be started from the beginning. Note that
each attempt will cause a radio
substitution alarm to be sent to the central
station.