schmersal SFB-PN-IRT-8M12-IOP Operating Instructions Manual

schmersal SFB-PN-IRT-8M12-IOP Operating Instructions Manual

Safety fieldbox
Hide thumbs Also See for SFB-PN-IRT-8M12-IOP:

Advertisement

Quick Links

Operating instructions
Safety fieldbox
Operating instructions. . . . . . . . . . . .pages 1 to 12
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
3.3 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .5
4.2 Power supply and fuse protection . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.3 Internal fuse elements device ports . . . . . . . . . . . . . . . . . . . . . . . . .5
4.4 Earth concept and shielding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
4.5 Overview of connections and LED indicators . . . . . . . . . . . . . . . . .6
4.7 Connector configuration POWER I/O . . . . . . . . . . . . . . . . . . . . . . .7
4.8 Connector configuration PROFINET P1/P2. . . . . . . . . . . . . . . . . . .7
4.9 Setting the F-address and factory reset. . . . . . . . . . . . . . . . . . . . . .7
5
5.1 LED indicators, device ports X0 - X7 . . . . . . . . . . . . . . . . . . . . . . . .7
5.2 LED indicators, PROFINET ports P1/P2 . . . . . . . . . . . . . . . . . . . . .8
5.3 Central LED indicators, SFB-PN . . . . . . . . . . . . . . . . . . . . . . . . . . .8
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
8
8.1 Configuration examples of the power supply . . . . . . . . . . . . . . . . . .9
8.2 Wiring example of the safety switches. . . . . . . . . . . . . . . . . . . . . .10
9
EU Declaration of conformity
1. About this document

1.1 Function

These operating instructions provide all the information required for
mounting, commissioning, safe operation and also disassembly of the
safety fieldbox. The operating instructions must be available in a legible
condition and a complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety fieldbox must only be used according to the following
versions or for applications that are approved by the manufacturer.
Detailed information regarding the range of applications can be found in
the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
EN
SFB-PN-IRT-8M12-IOP
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SFB-PN-IRT-8M12-IOP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SFB-PN-IRT-8M12-IOP

  • Page 1: Table Of Contents

    4.9 Setting the F-address and factory reset..... .7 Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: Diagnostic functions www.schmersal.net.
  • Page 2: Warning About Misuse

    Protection type: IP65/IP67 to IEC 60529 2.2 Purpose Protection class: The SFB-PN-IRT-8M12-IOP safety fieldbox is designed for connection Insulation values to IEC 60664-1: of up to 8 safety switchgear units with parallel IO signals to a - Rated insulation voltage U 32 VDC PROFINET/PROFIsafe network.
  • Page 3: Safety Classification

    Operating instructions Safety fieldbox SFB-PN-IRT-8M12-IOP Test pulse outputs: Y1 and Y2 2.4 Safety classification Switching elements: p-type, short-circuit proof - Safety inputs, 2-channel: Rated operating voltage U 24 VDC Standards: IEC 61508, IEC 62061, ISO 13849-1 Rated operating current I...
  • Page 4: Mounting

    VFB-SK8P/4P-M12-S-G-2,5M-BK-2-X-A-4 103032864 5.0 m VFB-SK8P/4P-M12-S-G-5M-BK-2-X-A-4 103032865 Y-Adapter cables for Schmersal AOPD 1.0 m SFB-Y-SLCG-COM-8P-S-G-1M-BK-2-X-A-4 103032866 1.0 m SFB-Y-SLCG-8P-S-G-1M-BK-2-X-A-4 103032867 3.3.3 Colour codes of the Schmersal cables Power M12, 4-pole M12, 8-pole Conductor colour Conductor colour Brown White White Brown 25,6...
  • Page 5: Electrical Connection

    Operating instructions Safety fieldbox SFB-PN-IRT-8M12-IOP 4. Electrical connection 4.4 Earth concept and shielding A functional earth is connected for fault-free operation of the safety 4.1 General information for electrical connection fieldbox. Earth loops must be avoided when connecting the functional To supply the safety fieldbox, M12 power connectors, cables with a earth.
  • Page 6: Overview Of Connections And Led Indicators

    Operating instructions Safety fieldbox SFB-PN-IRT-8M12-IOP 4.5 Overview of connections and LED indicators Device port X0 – X3 Device port X4 – X7 with FB interface for BDF200-FB Error LED X3 Error LED X7 Device port X3 Device port X7 Input LED X3...
  • Page 7: Connector Configuration Of Device Ports X0 - X7

    Receive-Data - Flange Ethernet shielding LED display Description YELLOW Both safety inputs LOW * Colour code of SCHMERSAL M12 cables YELLOW Both safety inputs HIGH YELLOW Flashes Only one safety input HIGH, 4.9 Setting the F-address and factory reset or discrepancy/stable time fault Carefully remove the viewing window.
  • Page 8: Led Indicators, Profinet Ports P1/P2

    Operating instructions Safety fieldbox SFB-PN-IRT-8M12-IOP 6. Set-up and maintenance 5.2 LED indicators, PROFINET ports P1/P2 There are 2 LED indicators at the Ethernet ports. A green link LED and yellow activity LED. 6.1 Functional testing A check must be carried out to ensure that the projected safety function LED link (L) is effective.
  • Page 9: Configuration

    3 different configurations are shown respectively for the different • For interlocks, these designs are based on simultaneous activation of SCHMERSAL safety switchgear. One configuration with long cable all lock and unlock functions. In the event of delayed activation of the lengths (maximum), one configuration with medium cable lengths lock and unlock function, larger systems are possible.
  • Page 10: Wiring Example Of The Safety Switches

    Electronic interlock, interlock function via 1 wire Electronic sensor, 8-pin Safety Switch Safety Switch Diag-Out Diag-Out SCHMERSAL devices: MZM 100, AZM 201, AZM 300, … SCHMERSAL devices: CSS series, RSS series, … Electronic interlock, interlock function via 2 wires Electronic sensor, 4/5-pin Safety Switch Safety Switch...
  • Page 11 2 electromechanical switches, 1-channel, forcibly interrupted Safety Switch Emitter Safety Switch SCHMERSAL devices: SLC 440 COM, SLG 440 COM, SLB 440, … Other wiring examples can be found in the 'Safety SFB-PN fieldbox manual' on the internet at www.schmersal.net. Different safety switchgear...
  • Page 12 Safety fieldbox SFB-PN-IRT-8M12-IOP 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

Table of Contents