3.2 Owner / Operator Control Buttons, Check System LED and Audio Alarm

The following is a brief explanation of owner or operator control buttons.
PLEASE NOTE:
This section assumes the installer has already programmed the system for specific
site parameters, has established proper water balance, and has pretreated water to
1 - 3 ppm (mg/L) chlorine.
ATTENTION OWNER:
Should Celsius vs. Fahrenheit, choice of language, or other owner options require
modification, refer to the Programming section of this manual. See "Review Of
Installer, Owner, & Maintenance Menu Programming" on page 21.
3.2.a UP and DOWN Arrows
Use the UP and DOWN arrows to control the purifier output level.
After output level is adjusted, press the SELECT button to save the value chosen. With a
properly prepared pool, the recommended starting output level is 50%.
Upon initial start-up, check sanitizer every 3-4 days and make small output level adjustments as
necessary to maintain 1 - 3 ppm (mg/L) free chlorine levels. Keep in mind, your Pool Pilot
not directly measure or regulate the sanitizer levels in your pool. Rather, the owner / operator will
need to periodically test the water to determine the current chlorine level, and adjust the output
setting as needed.
After the chlorine output level is "tuned in," the unit will automatically make fine output
adjustments as the water temperature fluctuates. This temperature compensation feature will
adjust output depending on water temperature. See "Patented Temperature Compensation" on
page 8.
PLEASE NOTE:
The optimum output setting will vary based upon pool size, location, exposure to
sunlight, number of users, vegetation around the pool, water balance practices,
and pump run time. Your installer should have already taken these factors into
consideration when performing installation programming. Therefore, your
adjustments, at this point, should be relatively minor.
3.2.b The BOOST Button
The BOOST button increases output to 100%. Use this feature when a heavier than normal
bather load is anticipated.
Press BOOST once...................................... = 24 Hour Boost
Press and hold BOOST for 8 seconds...... = 72 Hour Boost
Press BOOST a second time...................... = Deactivate Boost