Advance Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick
Absolute Maximum Ratings:
Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device.
Characteristic
Continuous Input Voltage
Transient Input Voltage
Isolation Voltage
Input to Output
Input to Baseplate
Output to Baseplate
Storage Temperature
Operating Temperature Range (Tc)
* Engineering estimate.
Input Characteristics:
Unless otherwise specified, specifications apply over all Rated Input Voltage, Resistive Load, and Temperature conditions.
Characteristic
Operating Input Voltage
Maximum Input Current
Turn-on Voltage
Turn-off Voltage
Hysteresis
Startup Delay Time from application of input voltage
Startup Delay Time from on/off
Output Voltage Rise Time
Inrush Transient
Input Reflected Ripple
Input Ripple Rejection
*Engineering Estimate
Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of
10A is required; see the Safety Considerations section of the data sheet.
©2002-2005 TDK Innoveta Inc.
iQAFullDatasheet080505 2.doc 8/3/2006
Min
Max
Unit
-0.5
80
Vdc
---
100
Vdc
---
1500
Vdc
---
1500
Vdc
---
500
Vdc
-55
125
˚C
-40
105*
˚C
Min
Typ
Max
36
48
75
---
---
3.0*
---
34
---
30*
32
---
0.5*
2
---
---
12
---
---
10
---
---
50
---
---
---
0.1
---
15
---
---
50*
---
℡
(877) 498-0099
Notes & Conditions
100mS max.
Basic insulation
Basic insulation
Operational insulation
Maximum baseplate temperature.
Unit
Notes & Conditions
Vdc
A
Vin = 0 to Vin,max
Vdc
Vdc
Vdc
Vo = 0 to 0.1*Vo,nom; On/Off =on,
mS
Io=Io,max, Tc=25˚C
Vo = 0 to 0.1*Vo,nom; Vin = Vi,nom,
mS
Io=Io,max,Tc=25˚C
Io=Io,max,Tc=25˚C, Vo=0.1 to
mS
0.9*Vo,nom
2
A
s
See input/output ripple measurement
mApp
figure; BW = 5 MHz
dB
@120Hz
4/19