Features
Standard Dual Quarter Brick format
A single module which can support
all your dual voltage requirements
between 1.5V and 5.5V
Two output trim options:
Standard Dual Trim – wide range
o
independent adjustment of either
output, using two trim pins
Optional Single Tracking Trim –
o
adjust both outputs together by 10%
according to industry standard
resistor tables
Independently regulated, tight
tolerance outputs
Flexible loading: 0-15A from either
output, 15A total load
High efficiency – up to 89%
Industry-leading output power: 75W
Basic insulation – 1500 Vdc
Full, auto-recovery protection:
Input under and over voltage
o
Output over voltage
o
Current limit
o
Short circuit
o
Thermal limit
o
©2001-2006 Innoveta™ Technologies, Inc.
iQAFullDatasheet080505 2.doc 8/3/2006
Dualeta™ iQA Series DC/DC Power Modules
The Dualeta™ Family is a 75W family of highly versatile,
independently regulated, dual output quarter brick
power modules with output voltage tracking. Its output
current loading scheme is fully flexible: 0 to 15A can be
drawn from either output with no minimum load
requirements. An ultra wide range independent output
trim allows the realization of dual output voltage
combinations between 1.5 and 5.5V. The superior
versatility of the Dualeta™ family substantially reduces
the quantity of distinct part numbers in the end user part
portfolio, lowering cost of ownership.
Monotonic, tracking start-up
Starts with pre-biased outputs
High reliability open frame, surface
mount construction
Baseplate for improved thermal
management
UL 60950 (US and Canada), VDE 0805,
CB scheme (IEC950)
Patented Technology
Options
Optional Single Tracking Trim – using
industry standard resistor tables
Remote on/off (negative logic)
Short Thru-hole pins 2.79 mm (0.110")
(877) 498-0099
48V Input, 15A Output
Dual Output Quarter Brick
1/19

Advertisement

Table of Contents
loading

Summary of Contents for TDK Dualeta iQA Series

  • Page 1 Data Sheet: Dualeta™ iQA Series – Dual Quarter Brick Features • Standard Dual Quarter Brick format • A single module which can support all your dual voltage requirements between 1.5V and 5.5V • Two output trim options: Standard Dual Trim – wide range independent adjustment of either output, using two trim pins Optional Single Tracking Trim –...
  • Page 2: Ordering Information

    36V to 75V 3320 Matrix Drive Suite 100 Richardson, Texas 75082 Phone (877) 498-0099 Toll Free (469) 916-4747 (877) 498-0143 Toll Free (214) 239-3101 support@tdkinnoveta.com http://www.tdkinnoveta.com/ ©2001-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Input Output Output Main Voltage Current/ Units Output...
  • Page 3: Mechanical Specification

    Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x ± 0.5 [0.02], x.xx and x.xxx ± 0.25 [0.010]. Recommended Hole Pattern: Pin Assignment: FUNCTION Vin (+) On/Off (-) Vin (-) Vo2 (+) ©2001-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 (top view) FUNCTION Output RTN Vo1 Trim (Optional: Single tracking trim pin) Vo1 (+)
  • Page 4: Absolute Maximum Ratings

    Caution: The power modules are not internally fused. An external input line normal blow fuse with a maximum value of 10A is required; see the Safety Considerations section of the data sheet. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Unit Notes &...
  • Page 5 Output Over Voltage Protection Tracking trim option External Load Capacitance Isolation Capacitance Isolation Resistance *Engineering Estimate & Contact Innoveta for applications that require additional capacitance or very low ESR capacitor banks. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Unit 3.25 3.35 2.46 2.54 3.20...
  • Page 6: Electrical Characteristics

    Typical Output 1 Voltage vs. Load Current at Ta = 25°C. Typical startup characteristic from On/Off application at full load. CH3-On/Off, CH1-Vo1, CH2-Vo2 ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Vin = 75V Typical Power Dissipation vs. Input Voltage at Ta=25°C.
  • Page 7 Voltage at Ta=25 degrees. Typical Output Ripple at nominal Input voltage and full balanced load currents at Ta=25 degrees. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Typical Vo2 load transient response. Io2 step from 3.75A to 7.5A with 0.1A/uS, Io1=7.5A. CH1 – Vo1, CH2 – Vo2, CH4 –...
  • Page 8 56.9 Rdown (kΩ) Rdown is connected between Trim and Vout2. Trim resistor values for output voltage adjustment – tracking trim option. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Io1 = Io2 = 0A Io1 = Io2 = 7.5A Typical Vo2 Output Voltage vs. Input Voltage Characteristics 12.1...
  • Page 9 Dual independent trim – standard Tracking trim option External Load Capacitance Isolation Capacitance Isolation Resistance *Engineering Estimate & Contact TDK Innoveta for applications that require additional capacitance or very low ESR capacitor banks. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Unit 4.92 5.08 3.25...
  • Page 10 Typical Output 1 Voltage vs. Load Current at Ta = 25°C. Typical startup characteristic from On/Off application at full load. CH3-On/Off, CH1-Vo1, CH2-Vo2 ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Vin = 75V Typical Power Dissipation vs. Input Voltage at Ta=25°C.
  • Page 11 Voltage at Ta=25 degrees. Typical Output Ripple at nominal Input voltage and full balanced load currents at Ta=25 degrees. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Typical Vo2 load transient response. Io2 step from 3.75A to 7.5A with 0.1A/uS, Io1=7.5A. CH1 – Vo1, CH2 – Vo2, CH4 –...
  • Page 12 (%) Rdown (kΩ) Rdown is connected between Trim and Vout2. Trim resistor values for output voltage adjustment – tracking trim option. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Io1 = Io2 = 7.5A Io1 = Io2 = 0A Typical Vo2 Output Voltage vs. Input Voltage Characteristics Trim down –...
  • Page 13 Thermal Management section. Due to the large number of variables in system design, Innoveta recommends that the user verify the module’s thermal performance in the end application. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006...
  • Page 14: Thermal Management

    (where applicable) and a parallel facing PCB is kept at a constant (0.5 in). The power module orientation with respect to the airflow ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 direction can have a significant impact on the module’s thermal performance.
  • Page 15: Operating Information

    Please contact Innoveta Engineering for recommendations on this subject. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 The system designer must use an accurate estimate or actual measure of the internal airflow rate and temperature when doing the heatsink thermal analysis.
  • Page 16 A small 0.01uF capacitor between the power module’s trim pin and RTN pin may help avoid this. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006 Two trim configurations are offered on the iQA-series. The standard Dual Independent...
  • Page 17 Electrical Characteristics section for trim adjustment. The current limit set point does not increase as the module is trimmed down, so the available output power is reduced. ©2002-2005 TDK Innoveta Inc. iQAFullDatasheet080505 2.doc 8/3/2006  4.01 %Vo ⋅...
  • Page 18: Warranty

    TDK Innoveta’s comprehensive line of power solutions includes efficient, high-density DC-DC converters. TDK Innoveta offers a three-year limited warranty. Complete warranty information is listed on our web site or is available upon request from TDK Innoveta. ©2002-2005 TDK Innoveta Inc.
  • Page 19: Safety Considerations

    All sales are subject to TDK Innoveta’s Terms and Conditions of Sale, which are available upon request. Specifications are subject to change without notice.

This manual is also suitable for:

Dualeta iqa48015a050m-000Dualeta iqa48015a033m-000

Table of Contents