413
Online receive buffer is full. Check for a flow control
problem.
611
Font, bar code, or density in the batch does not fit the
format.
612
The data in this line of the batch is either missing or
does not match the format.
613
Reference point off supply.
614
Portion of field off supply or there may be an invalid
character in the packet.
703
The printer sensed a calibration of different-sized black
marks. Make sure the correct supply type is loaded.
704
Printer has not sensed a supply mark within the
specified number of inches or is out of supplies. Check
the supply tracking, supply marks, black mark sensor
position, and supply roll for binding. Press
Escape/Clear and try to continue printing. Change
supply.
715
Invalid data length/data mismatch. The data in the
RFID Data Field has an incorrect data length or there is
a data type mismatch between selected data type and
actual data entered. The printer accepts either 8 bytes
(64-bit) or 12 bytes (96-bit) of data in the RFID Data
Field. For more information about the data length and
data type, refer to your RFID Application Notes. The
printer does not recalibrate (feed a blank label) after
any RFID error. Also, make sure you did not send
96-bit data to a 64-bit RFID tag. Check with your
System Administrator about your format.
740
Command, hardware, inventory, or memory allocation
error. There may be an RFID hardware or memory
allocation error. The printer does not recalibrate (feed
a blank label) after any RFID error. For more
information, refer to your RFID Application Notes.