Error Messages - SCP SCIENCE DigiPREP Series Service Manual

Table of Contents

Advertisement

freight charges for service parts purchased after the warranty
period.
4. SCP SCIENCE reserves the right to request that failed parts be returned
to a location specified by SCP SCIENCE, in which case freight charges
shall be borne by (distributor). This clause shall apply irrespective of
whether the unit is under warranty or not.
5. A DigiPREP digestion system that does not operate upon receipt ('out-of-
box failure') may be returned to SCP SCIENCE with transport charges to
the account of SCP SCIENCE. Note that the distributor must obtain a
Return Authorization number from SCP SCIENCE before shipping the
instrument. SCP SCIENCE reserves the right to select the method of
transport.
6. (Distributor) agrees to cooperate in all respects with SCP SCIENCE and
will provide SCP SCIENCE with service failure information, serial numbers
of the digestion block and/or controller, and any other service related
information determined by SCP SCIENCE as being relevant to the repair
of an instrument and to the improvement of the product.
7. An RMA # is required prior to returning any item to SCP SCIENCE.
8. SCP SCIENCE shall not be responsible for any damage or losses
however caused, which may be experienced as a result of the installation
or use of this product.

1.1 ERROR MESSAGES

Some of these error messages will not appear on older equipment.
1. DigiPROBE ERROR - ensure the DigiPROBE or the DigiPROBE Dongle
is installed correctly.
2. Over Temperature Protection - the block is over heating the set point
temperature check the SSR section 3
3. Temperature Dropping - DigiPROBE is no longer in the solution and
could be measuring vapor temperature.
4. Check DigiPROBE and DigiSET Dongle - The set point temperature has
not been reached. But steady state has been reached.
5. Steady State Error. The system is detecting a constant temperature but
has not reached set point temperature.
6. Temperature Unsteady – the DigiPROBE appears to be sensing a
variation in temperature typical caused when the DigiPROBE is or is about
to become out of the solution due to evaporation.
7. Set point Exceed Sample Boiling Point – Verify the set point entered.
Note: Any of these error messages will be eliminated upon the pressing of any
key. Elapsed time is not interrupted in this sequence.
KeyPad service manual
Rev.1.1
5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DigiPREP Series and is the answer not in the manual?

Questions and answers

Related Products for SCP SCIENCE DigiPREP Series

This manual is also suitable for:

Digiprep htDigiprep jr.Digiprep hpDigiprep ms

Table of Contents

Save PDF