Satel TSD-1 Manual
Satel TSD-1 Manual

Satel TSD-1 Manual

Smoke and heat detector

Advertisement

Quick Links

TSD-1
Smoke and heat detector
Firmware version 1.00
tsd-1_en 11/19
SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TSD-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Satel TSD-1

  • Page 1 TSD-1 Smoke and heat detector Firmware version 1.00 tsd-1_en 11/19 SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gdańsk • POLAND tel. +48 58 320 94 00 www.satel.eu...
  • Page 2 Changes, modifications or repairs not authorized by the manufacturer shall void your rights under the warranty. SATEL aims to continually improve the quality of its products, which may result in changes in their technical specifications and software. Current information about the changes being introduced is available on our website.
  • Page 3 The TSD-1 multisensor detector can detect the early stages of fire development when there is some visible smoke and/or temperature rise. This manual applies to the detector with electronics version 1.5 or higher. 1. Features  Selection of detector operating mode: –...
  • Page 4 TSD-1 SATEL When connecting an output to a SATEL control panel, you can use the built-in EOL resistors of the detector (2 x 1.1 k). The control panel’s input should be programmed as 2EOL. Removing the detector’s cover or cutting off the wires in such configuration will trigger a tamper alarm.
  • Page 5: Configuring The Detector

    SATEL TSD-1 additional location for detector installation. 4. Installation Disconnect power before making any electrical connections. 1. Remove the plastic dust cap. 2. Turn the cover counter-clockwise (Fig. 8) and remove it (Fig. 9). 3. Using wall plugs (anchors) and screws, secure the enclosure base to the wall. Select wall plugs specifically intended for the mounting surface (different for concrete or brick wall, different for plaster wall, etc.).
  • Page 6 TSD-1 SATEL DIP-switch position DIP-switch number Parameter relay type alarm memory disabled enabled heat detection disabled enabled smoke detection disabled enabled Table 2. Configuring the detector operating parameters with the DIP-switches shown in Fig. 4. If you disable smoke detection and heat detection, an error will be indicated by the detector's LED flashing.
  • Page 7 SATEL TSD-1 5. Maintenance The detector should be subjected to regular checks for correct functioning. The periodic checks should be carried out at least every 6 months. 6. Cleaning the optical chamber It is recommended that you have the optical chamber cleaned at least once a year. Cleaning the chamber is necessary when the LED indicates fouling of the chamber (one flash every 30 seconds).
  • Page 8: Specifications

    Enclosure dimensions.........................ø108 x 61 mm Weight................................164 g The TSD-1 smoke and heat detector conforms to the essential requirements of the EU Regulations and Directives: CPR 305/2011 Regulation of the European Parliament and of the Council of 9 March 2011 laying down harmonized conditions for the marketing of construction products and repealing the Council Directive 89/106/EEC on construction products;...