Specifications - General DAMP60 User Manual

Auto ranging 600a ac clamp meter/auto ranging ac/dc true rms 400a clamp meter
Hide thumbs Also See for DAMP60:
Table of Contents

Advertisement

Available languages

Available languages

DAMP60_68_MANUAL_FINAL_F-111511_awb 11/15/11 3:24 PM Page 18

SPECIFICATIONS

Parameter or
Feature/Function
AC voltage
DC voltage
AC current
DC current
Resistance
Frequency
Capacitance
Continuity
Diode integrity
18
Specification
Measurement ranges
Measurement accuracy
Measurement ranges
Measurement accuracy
Measurement range(s)
Measurement accuracy
Measurement range
Measurement accuracy
Measurement ranges
Measurement accuracy
Measurement range(s)
Measurement accuracy
Measurement ranges
Measurement accuracy
Threshold
Open circuit voltage
DAMP60
0 to 1.999V/ 19.99V/
199.9V/ 600V
±(1.0% + 5 digits)
0 to 199.9mV/1.999V/
19.99V/199.9V/600V
±(0.8% + 5 digits)
0 to 199.9A/600A
±(3% + 5 digits)
N/A
N/A
0 to 199.9Ω/ 1.999kΩ/
19.99kΩ/199.9kΩ/
1.999MΩ/19.99MΩ
±(1% + 5 digits)@<1MΩ;
±(2% + 5 digits)@≥1MΩ
10 to 1999Hz for
inputs from 0.2V to 30Vrms
±(3% + 10 digits)
N/A
N/A
30Ω
1.5V
DAMP68
0 to 400mV/ 4V/
40V/ 400V/ 600V
±(1% + 5 digits);
±(2% + 10 digits)
for 400mV range only
0 to 400mV/ 4V/ 40V/
400V/600V
±(0.8% + 5 digits)
0 to 400A
±(3% + 5 digits)
0 to 400A
±(3% + 5 digits)
0 to 400Ω/4kΩ/40kΩ/
400kΩ/
4MΩ/40MΩ
±(1% + 5 digits)@<1MΩ;
±(2% + 5 digits)@≥1MΩ
0 to 99.99Hz/999.9Hz/
9.999kHz/99.99kHz/999.9kHz/
9.999MHz for inputs
from 2V to 600Vrms
±2%
0 to 40nF/400nF/4 F/
40 F/ 400 F/4000 F
±(4% + 5 digits)
30Ω
2.7V
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Damp68

Table of Contents