All manuals and user guides at all-guides.com KERN ABT Operating instruction Analytical balance Technical data....................4 Declaration of conformity ................7 Keyboard and display overview ..............8 Keyboard overview ....................8 Overview of display ....................10 Basic Information (General)................ 11 Proper use.......................11 Improper Use ......................11...
Page 3
All manuals and user guides at all-guides.com Basic Operation ................... 34 11.1 Weighing .........................34 11.2 Taring ........................34 11.3 Changing the display....................35 11.4 Changing readability ....................36 11.5 Underfloor weighing....................37 The menu...................... 38 12.1 Changing settings ....................38 12.2 How to change settings ..................38 12.3 Call up menu ......................39 12.4...
All manuals and user guides at all-guides.com 2 Declaration of conformity KERN & Sohn GmbH D-72322 Balingen-Frommern Tel: 0049-[0]7433- 9933-0 Postfach 4052 Fax: 0049-[0]7433-9933-149 E-Mail: info@kern-sohn.de Internet: www.kern-sohn.de Declaration of conformity EC-Konformitätserklärung EC-Declaration of -Conformity EC- Déclaration de conformité EC-Declaración de Conformidad EC-Dichiarazione di conformità...
All manuals and user guides at all-guides.com 3 Keyboard and display overview 3.1 Keyboard overview In weighing mode: Pressed once and released Designa- Keep pressed for about 3 seconds tion [ON/OFF] [CAL] [TARE] [UNIT] [PRINT] [1d/10d]...
Page 9
All manuals and user guides at all-guides.com In menu: Designa- Keep pressed for about 3 se- Pressed once and released tion conds [ON/OFF] [CAL] [TARE] [UNIT] [PRINT] [1d/10d]...
All manuals and user guides at all-guides.com 4.4 Monitoring of Test Resources 5 Basic Safety Precautions 5.1 Pay attention to the instructions in the Operation Manual 5.2 Personnel training 6 Transport and storage 6.1 Testing upon acceptance...
All manuals and user guides at all-guides.com 7 Unpacking, Setup and Commissioning 7.1 Installation Site, Location of Use Therefore, observe the following for the installation site: 7.2 Unpacking...
Page 16
All manuals and user guides at all-guides.com 7.2.1 Scope of delivery Serial accessories:...
Page 17
All manuals and user guides at all-guides.com 7.2.2 Installation...
All manuals and user guides at all-guides.com 8.2 Automatic adjustment via Clock-CAL (only models ABT 100-5M, ABT 120-5DM, ABT 220-5DM) [ON/OFF] Clock-CAL function ON/OFF: [CAL] [TARE] [CAL] [TARE] [CAL] “tCAL-on” “tCAL-oF” [TARE] [ON/OFF]...
Page 23
All manuals and user guides at all-guides.com 8.2.1 Setting the time for Clock-CAL [CAL] [TARE] [CAL] [TARE] [PRINT] [UNIT] [UNIT] [TARE] [CAL] [ON/OFF] Clearing the Settings...
All manuals and user guides at all-guides.com 8.3 Adjustment via preset process [CAL] [TARE] 8.3.1 Selecting default adjustment method [CAL] [TARE] [TARE] [CAL] [TARE] [ON/OFF] [CAL] [TARE]...
Page 25
All manuals and user guides at all-guides.com 8.3.2 Default setting: Adjustment with internal weight [CAL] [TARE] 8.3.3 Default setting: Adjustment test with internal weight [CAL] [TARE]...
Page 26
All manuals and user guides at all-guides.com 8.3.4 Default setting: Adjustment test with external weight [CAL] [TARE]...
All manuals and user guides at all-guides.com 8.4 Carrying out alternative adjustment methods 8.4.1 Adjustment with internal weight [CAL] [TARE] [TARE] [CAL] [TARE]...
Page 28
All manuals and user guides at all-guides.com 8.4.2 Adjustment test with internal weight [CAL] [TARE] [TARE] [CAL] [TARE]...
Page 29
All manuals and user guides at all-guides.com 8.4.3 Adjustment test with external weight [CAL] [TARE] [TARE] [CAL] [TARE]...
All manuals and user guides at all-guides.com 9 Verification Verification of the balance is invalid without the "seal". Balances with obligation to verify must be taken out of operation if: weighing result error limit. reverification...
All manuals and user guides at all-guides.com 10 ISO/GLP log 10.1 Setting the log printout of your adjustment data [CAL] [TARE] [CAL] [TARE] [CAL] “GLP-on” “GLP-oF” [TARE] [ON/OFF]...
All manuals and user guides at all-guides.com 10.3 Setting the date printout [CAL] [TARE] [CAL] [TARE] [CAL] “Prtdt-on” “Prtdt-oF” [TARE] [ON/OFF] 10.3.1 Printout Date and Time, without weight value [PRINT]...
All manuals and user guides at all-guides.com 11.3 Changing the display [UNIT] [Pcs] [ct] Different settings have to be activated in the menu: [CAL] [TARE] [CAL] [TARE] [CAL] [TARE] [TARE] [ON/OFF]...
All manuals and user guides at all-guides.com 11.5 Underfloor weighing CAUTION Always ensure that all suspended objects are stable enough to hold the desired goods to be weighed safely (danger of breaking). Never suspend loads that exceed the stated maximum load (max) (danger of breaking) Always ensure that there are no persons, animals or objects that might be dam- aged underneath the load.
All manuals and user guides at all-guides.com 12 The menu 12.1 Changing settings Call up menu Set function Confirm and store ON/OFF, CAL TARE 12.2 How to change settings CAL key TARE key TARE CAL key TARE key TARE ON/OFF key Brief actuation of ON/OFF key: Long actuation of ON/OFF key:...
All manuals and user guides at all-guides.com 13.2 Standstill display Setting the standstill display [CAL] [TARE] [CAL] [TARE] [CAL] "b-1" "b-1" "b-1" [TARE] [ON/OFF]...
All manuals and user guides at all-guides.com 14.3 Density determination 14.3.1 Density determination of solids Condition [CAL] [TARE] [CAL] [TARE] [UNIT] [PRINT] [TARE] [ON/OFF]...
Page 57
All manuals and user guides at all-guides.com [UNIT] [TARE] [CAL] 14.3.2 Determining density of liquids Condition [CAL] [TARE] [CAL] [TARE] [UNIT] [PRINT] [TARE] [ON/OFF]...
Page 58
All manuals and user guides at all-guides.com [UNIT] [TARE] [CAL]...
All manuals and user guides at all-guides.com 14.5 Add up mode [ON/OFF] [1d/10d] Activate function: [CAL] [TARE] [CAL] [TARE] [CAL] “ Adon-on” “ Adon-oF”...
Page 61
All manuals and user guides at all-guides.com [TARE] [ON/OFF] Add up: Operation Display 5 5 .0003 g [PRINT] 0 0 .0000 g 5 5 .0017 g 0 0 .0000 g 5 5 .0010 g 1 1 5.0030 g [ON/OFF]...
All manuals and user guides at all-guides.com 15 Data output 15.1 RS 232C interface PIN No. Signal 15.2 Data Formats (ex.) Polarity data Stability information (ex.) Polarity data Stability data...
All manuals and user guides at all-guides.com 15.4 Standard Settings Display Parity Baud Data Hand- for menu Delimiter (Bit Stop bit Rate format shake selection length) Selecting one of standard Settings: [CAL] [TARE] [CAL] [TARE] [ON/OFF]...
All manuals and user guides at all-guides.com 15.5 User Settings [CAL] [TARE] [CAL] [TARE] [CAL] “io.b:****” “io.d:****” “io.P:****” “io.S:****” “io.F:****” “io.H:****” [TARE]...
Page 68
All manuals and user guides at all-guides.com 15.5.1 Communication speed settings [CAL] Display during setting Setting specifics Display during setting Setting specifics [TARE] [ON/OFF] 15.5.2 Delimiter settings [CAL] Display during setting Setting specifics [TARE] [ON/OFF] 15.5.3 Parity settings [CAL] Display during setting Setting specifics [TARE] [ON/OFF]...
Page 69
All manuals and user guides at all-guides.com 15.5.4 Stop bit settings [CAL] Display during setting Setting specifics [TARE] [ON/OFF] 15.5.5 Input-output data format settings [CAL] Display during setting Setting specifics [TARE] [ON/OFF] Note 15.5.6 Handshake settings [CAL] Display during setting Setting specifics [TARE] [ON/OFF]...
All manuals and user guides at all-guides.com 16 Service, maintenance, disposal 16.1 Cleaning Spilled weighing goods must be removed immediately. 16.2 Service, maintenance 16.3 Disposal...
All manuals and user guides at all-guides.com 17 Instant help Error code table: Error code display Explication Remedy Possible causes of errors: When Symptom Possible causes Remedy...
Page 72
All manuals and user guides at all-guides.com [TARE] [UNIT]...