42 Warnings for the NSG Unit
Warning Message
Web client:
Control panel
communication
failure
Control panel:
LCD comm fail
Web client:
Control panel LEDs
board
communication
failure
Control panel:
LEDs comm fail
Web client:
GbE X Channel
Failed. Activating
Redundant Channel
Control panel:
Channel failed
Web client:
GbE X UDAD Data
Not Received
Control panel:
UDAD not recv
Web client:
Missing resources
Control panel:
Miss resources
Web client:
Cannot find BOOTP
server. Booting with
previous IP setting
Control panel:
BootP srvr fail
Description
Cannot establish
communication with
the control panel
module.
Cannot establish
communication with
the LEDs board
module.
Active GbE channel
failed and triggered
automatic switch to
redundant channel.
No UDAD packets
received over the GbE
link.
All 256 available
sockets are in use.
BOOTP server did not
respond within the
defined timeout, NSG
booted with its
previous IP settings.
Solution
Call Customer Support.
Call Customer Support.
Check all GbE connections.
Check if the link to the
switch is alive and
active.Check if the switch is
configured for UDAD.
Re-check VOD system
configuration.
Retry BOOT.
Verify that BootP server
is up and that the NSG
MAC is correct.
Contact Customer
Support.