Examples - Miele PDR 507 EL Marine Operating And Installation Instructions

Vented dryer
Table of Contents

Advertisement

Installation of the ducting

Examples

Connection to a ventilation stack
a Pipe with connector
(= individual parts in the Miele wall
pipe)
b Adapter for a flexible exhaust air
hose
c Ventilation stack, moisture-proof
Risk of toxic fumes due to the in-
take of poisonous exhaust gas.
The tumble dryer extracts air for dry-
ing from the room where the appli-
ance is installed. If the appliance is
operated at the same time as fire-
places or other technical equipment
in the area of influence in the installa-
tion room, toxic exhaust gases can
be sucked back in.
Exhaust air must not be vented into a
chimney or vent flue which is other-
wise in use and must not be chan-
nelled into ducting which ventilates
rooms with fireplaces.
66
Window connection
a Window connection (inserted in a
pane of Perspex)
b Adapter for a flexible exhaust air
hose
Condensation may run into the
tumble dryer.
Do not lay the exhaust air hose in
loops. Cut the exhaust air hose to
the required length.