Symbol PDT 8000 Series Quick Reference Manual page 29

Symbol pocket pc quick reference guide
Hide thumbs Also See for PDT 8000 Series:
Table of Contents

Advertisement

Q u i c k
Problem
A message ap-
pears stating that
your terminal's
memory is full.
Fail to communi-
cate with IrDA
printer.
When receiving
beamed data an
out of memory
message ap-
pears.
Beamed data
does not transmit.
R e f e r e n c e
Cause
Too many files
stored on the termi-
nal.
Memory allocation
too low.
Too many applica-
tions installed on the
terminal.
Distance from print-
er is between 5 inch-
es and 39 inches.
Obstruction inter-
fered with communi-
cation.
Application is not
enabled to run IrDA
printing.
Not enough free
memory available
for receiving data.
Terminals too close
together or too far
apart.
Insufficient room
lighting.
27
Solution
Delete unused memos and records.
You can save these records on your
computer.
Adjust the memory allocation. Select
Start, then Settings, and select the
System tab. Tap Memory and adjust
the slider.
If you have installed additional appli-
cations on your terminal, remove them
to recover memory. Select Start, then
Settings, and select the System tab.
Tap Remove Programs, select the
unused program and tap Remove.
Bring the terminal closer to the printer
or move it further away and attempt
communications again.
Check the path to ensure no objects
were in the way.
Printer support must be included with
the application to run IrDA printing on
the terminal. See your System Admin-
istrator.
Your terminal requires at least twice
the amount of memory available as
the data you are receiving. For exam-
ple, if you are receiving a 30K applica-
tion, you must have at least 60K free.
Confirm that the terminals are at least
5 inches and at most 39 inches apart.
Also ensure that there is a clear path
between the two devices.
Adjust the room lighting or move to a
different location.

Advertisement

Table of Contents
loading

Table of Contents