Download Print this page

Hengstler tico 731.2 Operating Instructions Manual page 2

Dc powered lcd-counter

Advertisement

Available languages

Available languages

Operating instructions tico 731.2
- DC powered LCD-Counter
The tico 731.2 is a battery powered LCD-counter with programmable
count input for contact or edge triggering. The following versions are
available:
Totalizer:
Tachometer (1/min):
Time counter (HHHH:MM:SS):
Time counter (HHHHHHH.HH):
1
Numeric PLC-display:
or with plug in screw terminal e. g. 0 731 201 S
1. Programming of the COUNT-Input (all versions)
In order to match your application, the COUNT-Input can be
programmed for high speed (7,5 kHz) or low speed counting (30 Hz
attenuated). Positive or negative edge is programmable as well.
hold down the front key
and switch power on
press button shortly
to changes values
press button shortly
press button shortly
press button longer (> 2 sec)
to confirm the desired value
press button shortly
press button longer (> 2 sec)
to confirm the desired value
Count Mode
Zählmodus
Zählmodus
Count Mode
1
There is an extra operating instruction (No. 2 731 022) with protocol description for the numeric PLC-display.
2/6
standard
special
0 731 201
0 731 721
0 731 202
0 731 722
0 731 203
0 731 723
0 731 204
0 731 724
0 731 205
0 731 725
*
Note:
Maximum count speed
(7,5 kHz) and positive
edge triggered
Note:
low count speed (30 Hz
attenuated) and negative
edge triggered (e.g.
contacts)
Note:
low count speed (30 Hz
attenuated) and positive
edge triggered (e.g.
contacts)
* *
Note:
Maximum count speed
(7,5 kHz) and negative
edge triggered
Note:
front key is locked
Note:
*
front key is unlocked
*default values
**not applicable to time counters
NOTE:
The counter leaves the factory with the default value HI PNP
(f
7,5 kHz and positive edge triggered) and unlocked key.
max
To change the count input configuration:
2. Totalizer version (0 731 201)
Terminal 4 „RESET or Tacho-HOLD" is defined as the Reset-Input.
3. Tachometer version (0 731 202)
The tachometer operates via the gate measuring method. Within the
measuring time of 6 sec, the incoming pulses are counted and recal-
culated in order to display 1/min.
The Terminal 4 „RESET or Tacho-HOLD" is defined as the HOLD-Input
(as long as this Input is active, the actual value in the display is
frozen).
4. Time counters versions (0 731 203 and 204)
The time counters will count as long as the Count-Input (3) is active
(this can be a low or a high signal according to programming in
Chapter 1).
Terminal 4 „RESET or Tacho-HOLD" is defined as Reset-Input.
5. Terminal connection
Totalizer, Tacho, Time counters
6. Specifications
Power supply
Current consumption
Data retention
Display
Count input
active edge
Count frequency
Amplitude threshold
Reset input or
tacho hold
Key reset
Keylock
Mounting
Front dimension
Panel cut-out
Panel thickness
Product depth
Protection class
Operating temperature
Storage temperature
General rating
Protection class
Overvoltage
Contamination
Sach-Nr. 2 731 021; Version 1230699MW
1
Numeric PLC-Display
Terminal 1 and 2; 12..24 VDC
Tolerances: +20 -10%
5 mA, external overvoltage
protection 0,035 AT
non volatile RAM (NV), >10 years
LCD, 8-digit, 7 mm
Terminal 3 „Count"
programmable: NPN: negative
(e.g. Contact to ground 0V) or
PNP: positive signal
pulse length: min 70µs or
min 15 ms (if attenuated to 30 Hz )
programmable:
„HI" 7,5 kHz or „LO" 30 Hz
(attenuated for Contacts)
< 0,7 V and > 5 V, max 30 VDC
Reset with a negative edge on
„RESET", (Terminal 4 bridge to
Ground, 0V)
pulse length: min 15 ms
(attenuated to 30 Hz )
press front key shortly
programmable see chapter 1
Frontpanel mounted with clamping
frame
DIN 48 mm x 24 mm
+ 0,6
+ 0,3
45
mm x 22
mm
max. 14 mm
32 mm
front side IP 54
-10° C to +50°C
-20° C to +60°C
DIN EN 61010 part 1, VDE 0411 part 1
according to class II
category II
level 2
1170709MD1