3-7. Connection of UPS

Connecting procedure
1. Shut down the system or turn off the power of main
server.
2. Connect the FSV-VN7, FSV-CS7 and Tape Libraries
power cables to the UPS.
3. Connect a dedicated serial cable between the UPS and
the serial port on the rear panel of FSV-VN7.
4. Boot the FSV-VN7. The UPS is made available
automatically with the default setting.
(When the residual power capacity goes below 5% or
less than three minutes the UPS shuts the system down
automatically.)
For more information, refer to the UPS operation
manual.
3-20

3-8. UPS Setting

Setting of the UPS (enable/disable) is available with HNF
V1.30 or later.
Choose [Setup] → [Software Configuration] to open the
following window.
UPS Service
To enable the UPS, check the checkbox of UPS Service in
"Action ", and press the "Apply" button.
n
The UPS is disabled by the default setting.
"Apply" button
FSV-VN7/CS7