3-3-3. Verification of Firmware Revision

In this section, the update procedure of the LIB-162/A3 (AIT library)/ the internal AIT3 drive or the
CSM-20 (SAIT library)/internal SAIT1 drive is described.
The recommended firmware should be available at EMCS WW service website. Click "Firmware
Library" in the Service Information on the left-hand side and search by the model name.
Click [Firmware Revisions] in the Webmin [Service] menu and the current versions are displayed. When
the current version is old, a recommended version is suggested in red. A procedure for version up is
following.
http://bay99.ts.strg.sony.co.jp/index.php
[Process]
Stop PetaServe service.
Webmin: Services → Start/Stop of PetaServe
Upgrade the firmware by the menu.
Webmin: Services → Firmware Revisions
Check the firmware if it is same as the recommended version. If not, the "Update" icon should be high-
lighted. (If it is grayed out, PetaServe processes may be still running.)
Click the icon and chose the firmware file to upgrade the library.
Restart the PetaServe service after upgrade is completed.
Webmin: Services → Start/Stop of PetaServe
n
When the firmware matches with the recommended version, the update button becomes invalid.