IMPORTANT
Read and follow these instruc�ons carefully to ensure proper opera�on and warranty protec�on of your new paint shaker.

WARRANTY

Dedoes warrants the Cyclone Paint Shaker against defects due to defec�ve material, design or manufacturing to the end user for 3 years. The warranty
covers all manufactured parts on the shaker that are defec�ve or damaged. All products, goods, services and equipment comply with all applicable
environmental, safety, design and regulatory laws, regula�ons, customs and requirements of the region in which they are delivered and put into service.
This warranty does not cover any items that have been damaged due to mu�la�on, altera�on, misuse or abuse. Corrosion due to neglect or chemicals is not
covered by this warranty. Dedoes will not be responsible for loss of �me, inconvenience or other consequen�al damages.
Warranty is void: if there is any lack of lubrica�on and/or poor maintenance in which has caused the opera�on of the shaker to fail, if Dedoes parts are not
used for repairs or installa�on, and if shaker is not installed properly.
This is the only warranty on Dedoes products and no other expressed warranty by anyone other than Dedoes, in wri�ng, will be binding on the
manufacturer. This warranty is transferable from the loca�on of the original installa�on of the shaker to any addi�onal installa�on loca�on within the
warranty �me period.
Warranty return policy: Under no circumstances should the shaker or any part there-of be returned to Dedoes for inspec�on, replacement, and/or repair
without the wri�en consent from Dedoes.
WARNING
The Cyclone Shaker is approved for hazardous areas. This paint shaker is intended for use only by trained professionals in industrial work areas where public
and incidental access is prohibited. The manufacturer prohibits the sale or use for other purposes.
Use a standard petroleum 10W non-detergent rust inhibi�ng air tool oil, such as Lubriplate Rockwell 10R, or other air tool oil recommended for all air
cylinders and air tools. Do not use motor oil. The oil should have neither gum and varnish removers nor petroleum dis�llates. Never use silicone oils or
grease in a paint shop. The clear plas�c drip rate adjustment knob on the automa�c lubricator may crack or break if exposed to certain solvents and
synthe�c oils. Do not operate the shaker on compressed nitrogen or other inert gases without posi�ve ven�la�on of the work area.

INSTALLATION

Bolt the pedestal securely to the floor and bolt the shaker to the pedestal. See page 11 for instruc�ons and a template. The shaker may be bolted to a
bench or table top, however, the bench must be rigid or it will shake apart. See page 12 for instruc�ons and a template. Always seal the shaker housing to
the pedestal or bench top with non-silicone elastomeric sealant to prevent leaking and greatly reduce noise.
Temporary or portable installa�ons of the Shaker and Pedestal can be made by bol�ng the assembly to a 14 or 15 inch wheel and �re having a five-bolt
moun�ng pa�ern on a 4.75 or 5 inch bolt circle. See page 11 for instruc�ons and a template.
Mount the supplied lubricator to the shop air line and connect the shaker using a 1/4 inch (4 mm) inside diameter air hose that is no longer than four feet
(1.2M). The hose must be rated for 200 PSI (1300 kPa) or higher working pressure. Avoid air line low spots to prevent water traps. Connect the shaker as
shown by Op�on 1 below. Excessive moisture or any dirt in the airline must be prevented by installing an air filter as shown in Op�on 1. The lubricator may
be mounted directly onto the shaker shown by Op�on 2 below. Install the lubricator with the arrow poin�ng toward the shaker in the direc�on of the air
flow. Unscrew the lubricator bowl from the body. Fill the lubricator bowl with the supplied air tool oil to the fill line. Screw the bowl on straight to avoid
cross threading. The seal ring on the bowl of the lubricator body must be installed correctly for the lubricator to work. Check that the drip rate adjustment
knob is open and set to 4. Adjust the lubricator by turning the ver�cal line on the drip rate dial clockwise un�l it stops and then turning it counter clockwise
to number 4. Install a quick connect in the air line upstream of the control valve to allow manual lubrica�on when needed. If manual lubrica�on is required,
squirt a few drops of oil into the quick connect plug before each use.
OPTION 1:
Lubricator mounted onto wall with air filter.
Isola�on
Lubricator
Valve
Filter
Bowl
For technical support on our products or addi�onal accessories, please call us at 248-624-7710 or visit our web site: www.dedoes.com
Page 2
Cyclone Paint Shaker User Manual
Part No: 0910P (Shaker) / 0915P (Pedestal)
Quick
Connect
1/4 I.D.
Control
Air Hose
Valve
OPTION 2:
Lubricator mounted directly onto the shaker
Inlet
Quick
Fi�ng
Connect
Shaker
Inlet
Lubricator
Fi�ng
Brass
Control
Close
Valve
Nipple
Bowl
PART # M-312 KD RV.8 2019-09-25