Telecom Behnke a Series Manual page 83

Door intercom devices

Advertisement

Available languages

Available languages

extended operation
6.
6.1. Control options during voice calls
During voice calls, door intercom devices offer several control options to be activated using
a telephone with DTMF dialling:
Entry
Function
Activation
Activate relay
code #
The relay operations mode, the activation time and the activation code, naturally,
have to be set correctly to activate a relay via an activation code.
## x
Set volume to x (x=0 to 9)
The volume setting is only valid for the current connection. The volume can only
be permanently set via the configuration steps 06, 07, and 988.
##* security
Automatic acoustic setting (without additional amplifier) (V1.51 or later)
code 0
see next section
##* safety
Automatic acoustic setting (with additional amplifier) (V1.51 or later)
code 1
see next section
##* security
Automatic acoustic setting (maintain mode) (V1.51 or later)
code 2
see next section
###
Play voice message (V1.30 or later)
The voice message set for this function will be played.
*#
Disconnecting (function can be set via configuration step 9918 from V1.34 or
later)
**
Enter set-up mode (subsequently, enter security code)
*0
Switching between operation with and without additional amplifier
1x ok beep ▸ operation without additional amplifier
2x ok beeps ▸ operation with additional amplifier
Error beep ▸ operation with additional amplifier not possible or not permitted