Plug Design - Siemens 1FK7 02 Series Manual

Three-phase servomotors
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 9
L1
3
U2
U
Power connections
1FK7 02. - 1FK7 100
BR2
Connector size 1
Signal connections
Resolver
- Temp
S2
9
R1
1
10
S4
2
11
3
not
connected
not
connected
Fig. 5 Circuits
5.2

Plug design

Improper change of the plug output direction leads to damage to the connecting
cables.
Do not exceed the permissible twisting moments as per Fig. 6.
A maximum of ten changes to the plug output direction are permissible up to the
stop with the attached, matching, mating plug.
Power plug
1. Use plug size 1 or 1.5.
2. Assign the plugs according to figure Fig. 5 Connect the PE conductor.
3. Connect the brake via Fig. 5 the power plug.
Siemens AG
Supply
L2
L3
3
V2
W2
W
V
Motor
W
V
U
1
2
6
GNYE
4
5
BR
Incremental Encoder
+ Temp
P-Encoder
S3
(5V)
R3
5V
8
Sense
7
12
not
- Temp
6
conn.
+ Temp
5
4
not
0V
connected
Sense
S1
ENGLISH
U V W
3
M
Encoder
Motor
1FK7 101 / 1FK7 103
BR2
W
GNYE
sin/cos 1 V
PP
B -
B +
A +
A -
R -
11
1
10
2
R +
12
9
13
3
16
not
14
E
conn.
8
4
15
6
7
5
D -
D +
C +
M-Encoder
C -
(0V)
NOTICE
610.40 700.21
BR
BR2
(+)
(-)
BR
V
U
Connector size 1,5
Absolute Encoder
Simple Absolute Encoder
B -
B +
P-Encoder
5V Sense
11
1
10
12
13
9
16
- Temp
17
14
8
15
+ Temp
6
5
7
0V Sense
not
M-Encoder
connected
Brake
A +
A -
- Data
2
+ Data
3
not
conn.
4
not
conn.
- Clock
+ Clock
17

Advertisement

Table of Contents
loading

Table of Contents