O
PERATION PROCEDURE
If a function that is not available is selected, the
message NOT AVAILABLE will appear.
Operating procedure varies with heat pump type and
straight cooling type. Contact your Daikin dealer to
confirm your system type.
To protect the unit, turn on the main power switch
6 hours before operation.
If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.
NOTE
Set the temperature within the ranges mentioned
under
"Operation range" on page
Precautions for group control system or two remote
controller control system
This system provides two other control systems beside individual
control (one remote controller controls one indoor unit) system.
Confirm the following if your unit is of the following control system
type.
Group control system
One remote controller controls up to 16 indoor units.
All indoor units are equally set.
Two remote controller control system
Two remote controllers control one indoor unit (In case of group
control system, one group of indoor units). The unit is
individually operated.
NOTE
Contact your Daikin dealer in case of changing the
combination or setting of group control and two remote
controller control systems.
O
PTIMUM OPERATION
Observe the following precautions to ensure the system operates
properly.
Adjust the air outlet properly and avoid direct air flow to room
inhabitants.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.
Keep doors and windows closed. If the doors and windows
remain open, room air will flow out and decrease the effect of
cooling and heating.
Never place objects near the air inlet and the air outlet of the
unit. It may retard effectiveness or cause operation to stop.
Turn off the main power supply switch when not using for long
periods of time. Electricity is consumed as long as the switch is
on. Turn off the main power supply switch in order to save
energy. Turn on the main power supply switch 6 hours before
restarting operation in order to ensure smooth operation. (Refer
to
"Maintenance" on page
When the display shows "
FILTER), have a qualified service person to clean the filters.
(Refer to
"Maintenance" on page
FH(Y)B+C(P) + FDY(P) + FBQ + FCQ + FDQ
Split system air conditioners
4PW10622-1C
1.
4.)
" (TIME TO CLEAN AIR
4.)
N
OT A MALFUNCTION OF THE AIR CONDITIONER
The following symptoms do not indicate air conditioner malfunction.
The system does not operate
The system does not restart immediately after the ON/OFF
button is pressed.
If the OPERATION lamp lights, the system is in its normal
operating condition.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded.
The system will turn on again automatically after three minutes.
The
system
does
not
TEMPERATURE SETTING button is returned to its former
position after pushing.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded.
The system will turn on again automatically after three minutes.
The system does not start when the display shows "
(EXTERNAL CONTROL ICON) and it flashes for a few seconds
after pressing an operation button.
This is because the system is controlled or disabled by another
controller with a higher priority.
When the display flashes, it indicates that the system cannot be
controlled by this indoor unit.
The system does not start immediately after the power supply is
turned on.
Wait one minute until the micro computer is prepared for
operation.
The outdoor unit has stopped.
This is because the room temperature has reached the set
temperature. The unit switches to fan operation.
"
" (EXTERNAL CONTROL ICON) is displayed on the
remote controller and the actual operation is different from the
remote controller setting.
For multi split models, the micro computer executes the following
control depending on the operation mode of other indoor units.
-
Before you start to operate, the other indoor unit(s) is (are)
already operating. When the operation mode of this unit is
different from your choice, the indoor unit of your room may
be put in waiting condition. (Fan: Stop, Horizontal flap:
Horizontal position)
Your room
Cooling
Cooling
O
Dry
O
Fan only
O
Heating
W
O : your unit can operate
W : your unit in waiting mode
-
When the total cooling capacity of all indoor units which are
operating is beyond the capacity limit of the outdoor unit, your
indoor unit will be put in waiting condition. (Fan and
horizontal flap: Same as setting: (cooling only model only))
-
After cooling mode operation of the unit of your room, when
other unit(s) start to operate, the unit of your room may
operate as follows: Fan: L tab, Horizontal flap: Horizontal
position.
The fan speed is different from the setting. Pressing the fan
speed contol button does not change the fan speed.
When the room temperature reaches the set temperature in
heating mode, the capacity supply from the outdoor unit has
stopped and the indoor unit operates in fan only mode (L tab). In
case of multi split, the indoor unit alternately operates fan stop
and fan only mode (L tab).
This is to prevent the cool air from being blown directly onto
anyone present in the room.
restart
immediately
when
Operation mode
Other room(s)
Dry
Fan only
O
O
O
O
O
O
W
W
Operation manual
the
"
Heating
W
W
W
O
2