Electrical Controls - Champion P5-24 Installation/Operation Manual With Service Replacement Parts

Waste handling systems
Hide thumbs Also See for P5-24:
Table of Contents

Advertisement

POWER MUST BE TURNED OFF UNTIL ALL MECHANICAL CHECKS ARE COMPLETE.
The Remote Control Cabinet offers
the following controls:
A: ON/OFF manual reset breaker
switch.
Rotate handle fully CW to turn
power ON. Rotate handle fully
CCW to reset tripped breaker
and to lock-out breaker to service.
B: 3 amp manual reset circuit
breaker.
Push reset button in if 120VAC control
circuit breaker trips.
C: Red POWER ON indicator light.
Indicator illuminates when ON/OFF
breaker switch (A) is in the ON position.
D: Optional Deodorizer Injector
On/Off switch.
Push toggle switch ON to run the Injector.
The injector speed-control is located
inside the remote control cabinet. Amount
of deodorizer injected depends on the
customer's requirements.
E: Optional Delay/Stop switch
with adjustable 6-minute timer.
Push the Delay/Stop switch. Depending
on the timer setting, the system will
STOP after the preset time DELAY.
F: Optional Flushing Valve On/Off
selector switch.
Turn the selector switch ON and the
water extractor and/or pulper flushing
system will operate.
G: System START/STOP station
located on the water extractor.
Push the Start push button and the
waste handling system will run. Push
the Stop push button and the system
will shut-off.
Pulper/Water Extractor Electrical Controls
Remote Control Cabinet shown with deodorizer, delay stop, and flushing valve
options and the system Start/Stop Station located at the top of the water extractor.
Pulper/Water Extractor - Initial Start-up
START
RESET
LOCK
OFF
TRIP
ON
STOP
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

P7-30P5-27