Champion P5-24 Installation/Operation Manual With Service Replacement Parts page 21

Waste handling systems
Hide thumbs Also See for P5-24:
Table of Contents

Advertisement

Model P5-24, P5-27, P7-30 Pulper
Remote Start/Stop Station Option
Installation Instructions
An optional remote start/stop station may have
shipped inside the pulper tank for remote installation
by others. The remote station consists of two
push buttons in a metal enclosure.
Mounting hardware, flexible1/2" sealtite,
wiring and connectors are supplied by others.
Wire size must be 14 AWG. THHN (90ºC).
Refer to the wiring diagram below which shows
how the start/stop station is connected in the
pulper control circuit.
WARNING!!
Electrocution or serious injury may result when
working on an energized circuit. Disconnect power
at the main breaker or service disconnect switch
before working on the circuit. Lock-out and tag
the breaker to indicate that work is being performed
on the circuit.
The installation of the remote start/stop station should be performed by
qualified personnel who will observe all local safety, sanitary, and electrical
codes or in the absence of local electrical codes then personnel should follow the
National Electrical Code.
Refer to the Champion Service Manual, P/N 114509 for complete operating instructions for the
machine.
Optional Remote Start/Stop Station Installation
Remote Start/Stop Station Wiring Diagram
4CR
3
32
2CR
3
4
STOP
5
STOP
4
Remote
Stop
Remote Start/Stop Station
DELAY STOP
TIMER (IF USED)
TR
CLUTCH
1
4
7
2
START
M
30
6
8
6
5
OFF DELAY
6
6
5
Remote
Start
1CR
6
1/2" Sealtite
(supplied by others)
7
7
7
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

P7-30P5-27

Table of Contents