INSTALLATION INSTRUCTIONS
IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF
ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.
The Hosedown Series of commercial and industrial LED watertight fixtures is for ceiling applications with Suspension, pendant,
stem(conduit), or surface mount installation methods. The Hosedown Series is designed for use in 120/277V and 347/480V,
50/60Hz protected (max 20A) circuits. Size line voltage service wire as required per the National Electrical Code (NEC).
SUITABLE FOR OPERATION IN
AMBIENT NOT EXCEEDING ___ °C
PEUT ÊTRE UTILISÉ À UNE
TEMPÉRATURE AMBIANTE
N'EXCÉDANT PAS ___°C.
WARNING: DO NOT EXCEED
MAXIMUM RECOMMENDED
AMBIENT TEMPERATURES.
THE TABLE SHOWS THE MAXIMUM
AMBIENT FOR EACH MODEL.
SURFACE MOUNT REDUCES MAX
AMBIENT
5°C
.
GENERAL NOTES:
MAKE SURE ALL WIRE AND CONNECTORS ARE UL-LISTED. IF THE
1.
ELECTRICAL SYSTEM CONTAINS NO GROUNDING WIRE, CONSULT
WITH A QUALIFIED ELECTRICIAN BEFORE PROCEEDING WITH
THE INSTALLATION.
SUSPENSION CABLE OR CHAIN SHALL BE RATED TO SUPPORT
2.
WEIGHT OF FIXTURE(S) – INCLUDING ALL ACCESSORIES AND
OPTIONS. AIRCRAFT SUSPENSION CABLE MAY BE ORDERED
SEPARATELY FROM FLEX LIGHTING SOLUTIONS OR OTHERWISE
PROVIDE BY CONTRACTOR.
FLEXLIGHTINGSOLUTIONS.COM
REV 082318
Series/Model
Housing
HD20S-A1-06K-2N-xx-xx-BC
2N
2' Narrow
HD20S-A1-12K-2N-xx-xx-BC
HD20S-A1-06K-4N-xx-xx-CL
4N
HD20S-A1-12K-4N-xx-xx-BC
4' Narrow
HD20S-A1-24K-4N-xx-xx-CL
HD20S-A1-18K-2W-xx-xx-CL
2W
HD20S-A1-24K-2W-xx-xx-CL
2' Wide
HD20S-A1-30K-2W-xx-xx-CL
ITEMS NOT INCLUDED
(
BUT REQUIRED FOR INSTALLATION
PERSONAL PROTECTIVE EQUIPMENT
SCREWDRIVER
PLIERS
SUPPLY CONDUCTORS (BUILDING LINE POWER)
RECEPTACLE (IF APPLICABLE)
ITEMS INCLUDED:
FLEX LIGHTING SOLUTIONS LED LIGHT FIXTURE (WITH TWO SAFETY SCREWS)
CORD AND PLUG (OPTIONAL, SOLD SEPARATELY)
MAY ALSO INCLUDE SOME OPTIONAL ACCESSORIES (IF ORDERED)
REFER TO SPECIFICATIONS SHEET FOR ALL POSSIBLE OPTIONS.
LIGHTING.TECH@FLEXTRONICS.COM
HOSEDOWN SERIES
These instructions apply to the
following part numbers:
HD20S-A1-xx-2N-xx-xx-xx-xx-10V
HD20S-A1-xx-4N-xx-xx-xx-xx-10V
HD20S-A1-xx-2W-xx-xx-xx-xx-10V
Ambient Range
-13°F to 104°F
(-25°C to 40°C)
-13°F to 104°F
(-25°C to 40°C)
-13°F to 104°F
(-25°C to 40°C)
-13°F to 104°F
(-25°C to 40°C)
-13°F to 104°F
(-25°C to 40°C)
-13°F to 113°F
(-25°C to 45°C)
-13°F to 104°F
(-25°C to 40°C)
-13°F to 113°F
(-25°C to 35°C)
):
913.851.3000

Advertisement

loading

Summary of Contents for Flex Hosedown Series

  • Page 1 ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. The Hosedown Series of commercial and industrial LED watertight fixtures is for ceiling applications with Suspension, pendant, stem(conduit), or surface mount installation methods. The Hosedown Series is designed for use in 120/277V and 347/480V, 50/60Hz protected (max 20A) circuits.
  • Page 2 THEY ARE ON AND IN PROPER WORKING ORDER. CONFIRM ALL ELECTRICAL CONNECTIONS ARE COMPLETE AND CONTINUOUS. IF THE ISSUE REMAINS UNRESOLVED, CONTACT FLEX LIGHTING SOLUTIONS. ISSUE 2 - ONE OR MORE LEDS ARE OUT WHILE OTHERS REMAIN ON DETERMINE IF REPLACEMENT IS DESIRED. AFTER ONE OR MORE LEDS FAILS, THE FIXTURE MAY CONTINUE TO OPERATE NORMALLY, ALTHOUGH WITH A REDUCED LUMEN OUTPUT.
  • Page 3: Lighting.tech@Flextronics.com

    REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION. IF FIXTURE HAS A CORD, CHECK TO ENSURE CORD GROMMET IS TIGHT. IF NOT TIGHT, NOTIFY LIGHTING.TECH@FLEX.COM IMMEDIATELY SECURE SUSPENSION CABLE TO STRUCTURE. (ORDERED SEPARATELY – CABLEKIT OR CABLEKITSS FOR 2W MODEL OR CABLEKIT2P OR CABLEKIT2PSS FOR 2N AND 4N MODELS) OR CHAIN (NOT INCLUDED).
  • Page 4 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. SURFACE MOUNT (MLT) – 2N AND 4N MODELS ONLY PREPARING TO INSTALL REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION.
  • Page 5 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. 45° HANGER MOUNT – SEPARATELY ORDERED ACCESSORY (45M) – 2N AND 4N MODELS ONLY PREPARING TO INSTALL –...
  • Page 6: Make Final Wiring Connections (Refer To Wiring Instructions At End Of This Section), Fig

    HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. SURFACE MOUNT (FM2WSS) - (2W MODEL ONLY) PREPARING TO INSTALL REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION.
  • Page 7: Flexlightingsolutions.com Rev

    HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. RIGID STEM MOUNTING (MLT) - 2N AND 4N MODELS ONLY PREPARING TO INSTALL REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION.
  • Page 8: Lighting.tech@Flextronics.com

    HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. RIGID STEM MOUNTING (PENDSS) – 2W MODEL ONLY PREPARING TO INSTALL REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION.
  • Page 9 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. PLATE MOUNT (PLATESS) INSTALLATION REFER TO GENERAL INSTRUCTIONS 1 THROUGH 9 AT THE BEGINNING OF THIS SECTION.
  • Page 10 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. HANGER MOUNT – SEPARATELY ORDERED ACCESSORY (HANGERSS) - 2W ONLY PREPARING TO INSTALL – REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION.
  • Page 11: 6. Make Final Wiring Connections (Refer To Wiring Instructions At The End Of This Section

    HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. CUSTOMER SUPPLIED POWER CORD FIELD INSTALLATION PREPARING TO INSTALL – REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION.
  • Page 12 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. LENS REMOVAL AND REPLACEMENT REMOVING LENS REFER TO GENERAL INSTRUCTIONS AT THE BEGINNING OF THIS SECTION. IF INSTALLED, REMOVE 2 SAFETY SCREWS, 1 EACH ON OPPOSING SIDES.
  • Page 13 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. WATERPROOF SLEEVE INSTALLATION - (ORDERED AS AN OPTION - WPSLV) PREPARING TO INSTALL – ONLY USED FOR CORD AND PLUG APPLICATIONS.
  • Page 14 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. WIRING INSTRUCTIONS: MAKING FINAL ELECTRICAL CONNECTIONS – HARDWIRED WIRING THROUGH HOLE IN HOUSING: IDENTIFY AND REMOVE CAP AT SELECTED END OF HOUSING. EXTEND BUILDING POWER WIRING TO FIXTURE AND FEED THROUGH OPENING.
  • Page 15 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. FLEXLIGHTINGSOLUTIONS.COM LIGHTING.TECH@FLEXTRONICS.COM 913.851.3000 REV 082318...
  • Page 16 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. MICRO WAVE OCCUPANCY SENSOR - (ORDERED AS AN OPTION - MWOCC) For most up to date instructions, please visit: https://www.legrand.us/wattstopper.aspx SPECIFICATIONS-LEGRAND WATTSTOPPER FM-105 VOLTAGES..........120/277VAC, 50/60Hz...
  • Page 17 HOSEDOWN SERIES INSTALLATION INSTRUCTIONS IMPORTANT: READ ALL INSTRUCTIONS THOUROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF ESSENTIALS SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE. ADJUSTMENTS THREE TRIMPOTS ON THE FM-105 ALLOW YOU TO ADJUST THE TIME DELAY, SENSITIVITY/RANGE, AND LIGHT LEVEL SETPOINT. TO REDUCE A SETTING, TURN THE ASSOCIATED TRIMPOT COUNTER-CLOCKWISE TOWARD THE MINIMUM SETTING.