MAINTENANCE
2.
Keep the tops of the batteries clean and dry.
Keep the terminals and connectors clean. To clean
the top of the batteries, use a damp cloth with a
weak solution of ammonia or bicarbonate of soda
solution. To clean the terminals and connectors,
use a terminal and connector cleaning tool. Do
not allow ammonia or bicarbonate of soda to get
into batteries.
3.
Keep the batteries charged.
CAUTION!
The battery charger must be
reprogrammed when switching
from lead acid to AGM
batteries. See the Charger
Manual for instructions.
Do These Procedures When You End Your Work
Check the batteries and add distilled water as needed.
The correct level is within 1/4 inch of the bottom of the
tube in each cell.
CAUTION:
Tap water may contain contami-
nants that will damage batter-
ies. Batteries must be re-filled
with distilled water only.
WARNING: Lead acid batteries generate
gases which can cause an
explosion. NO SMOKING.
Always wear eye protection and
protective clothing when work-
ing near batteries.
Use a clean cloth and wipe the surface of the ma-
chine.