GREER Company Microguard 414 Operator's Manual

Rated capacity indicator (rci) system for lattice boom cranes
Hide thumbs Also See for Microguard 414:

Advertisement

Quick Links

GREER COMPANY
GREER COMPANY
GREER COMPANY
GREER COMPANY
MICROGUARD
MICROGUARD
MICROGUARD
MICROGUARD
RATED CAPACITY INDICATOR (RCI)
SYSTEM
SYSTEM
SYSTEM
SYSTEM
LATTICE BOOM CRANES
LATTICE BOOM CRANES
LATTICE BOOM CRANES
LATTICE BOOM CRANES
HORIZONTAL DISPLAY
HORIZONTAL DISPLAY
HORIZONTAL DISPLAY
HORIZONTAL DISPLAY
CLYDE M4190
CLYDE M4190
CLYDE M4190
CLYDE M4190
BARGE MOUNT
BARGE MOUNT
BARGE MOUNT
BARGE MOUNT
GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705
MicroGuard
414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL
Crane Systems
Crane Systems
Crane Systems
Crane Systems
414
414
414
414
   
OPERATOR'S MANUAL
OPERATOR'S MANUAL
OPERATOR'S MANUAL
OPERATOR'S MANUAL
1 of 21
Tel: 714) 259-9702
Fax: 714) 259-7626 PN W414107-
12/20/01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Microguard 414 and is the answer not in the manual?

Questions and answers

Summary of Contents for GREER Company Microguard 414

  • Page 1 BARGE MOUNT OPERATOR'S MANUAL OPERATOR'S MANUAL OPERATOR'S MANUAL OPERATOR'S MANUAL GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-  MicroGuard 414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL...
  • Page 2: General Warning

    This System may not be used as a substitute for the usual safety practices and precautions required for the safe setup and operation of cranes. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 3: Table Of Contents

    SETTING ALARMS – EXAMPLES A-C ..................16-17 CANCELING ALARMS........................18 PERIODIC INSPECTIONS.......................... 19 SYSTEM CHECKS......................... 20 ROUTINE MAINTENANCE......................20 GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-  MicroGuard 414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL...
  • Page 4: System Description

    Use of alternate display push buttons provide the operator with: ♦ Length of the Main Boom. ♦ Height of the Boom Head. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-  MicroGuard...
  • Page 5: The Display - Upper Left

    It includes the load, slings, pins, or tackle used to secure the load, and the hook block. Using the STOWED DEDUCT button, the operator can "tare out” the slings and hook (see page 9). GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 6: The Display - Upper/Lower Right

    On this crane, it will only display 360° (AS SHOWN). GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 7: Push Buttons - Lamps - Icons

    MAXIMUM RATED CAPACITY ICON (8) indicates the area of the left display that gives a read MAXIMUM RATED CAPACITY ICON MAXIMUM RATED CAPACITY ICON out of maximum rated capacity for the currently selected configuration. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 8: The Display - Left

    CLEAR ( ( ( ( 11) clears a current alarm. CONTRAST (DOWN) (12) decreases the display contrast. CONTRAST (UP) (13) increases the display contrast. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 9: The Display Upper Right

    CRANE SETUP (7) CRANE SETUP (7) configuration. This icon is also a push button used to start the selection of the crane configuration. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 10: The Display - Lower Right

    6 &7) are push buttons used in calibration routines. RIGHT AND LEFT ARROWS RIGHT AND LEFT ARROWS 6 &7) 6 &7) GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-  MicroGuard...
  • Page 11: System Operation

    WHEN FUNCTION KICK-OUT IS RESET USING THE CANCEL ALARM BUTTON, THERE IS NO LONGER PROTECTION AGAINST THE CONDITION THAT CAUSED THE FUNCTION KICK-OUT. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 12: Configuration Selection

    ANGLE OF THE MAIN BOOM. This information will remain on the display only as long as the operator continues to press and hold this push button. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 13 FOLLOWING THE SELECTION OF CRANE SET UP, USE THE WINCH PUSH BUTTON TO SELECT THE LIFTING POINT. SET THE PARTS-OF-LINE IN USE FOR EACH WINCH USING THE PARTS-OF- LINE PUSH BUTTON. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 14: Operator Settable Alarms

    CONTRAST OPERATOR ALARMS MINIMUM ANGLE MAXIMUM ANGLE MAXIMUM HEIGHT GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-  MicroGuard 414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL...
  • Page 15: Setting Alarms - Method

    NOTE: AN ALARM SHOWING A VALUE WHEN THE CURSOR IS NOT POINTING AT THE ALARM NOTE: NOTE: INDICATES A PREVIOUSLY SET VALUE. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 16: Setting Alarms - Examples A-C

    WORKING SCREEN. THE RED LAMP AND THE AUDIBLE ALARM WILL OPERATE WHENEVER THE BOOM IS ABOVE 60 DEGREES. THE MESSAGE MAX ANGLE WILL APPEAR IN THE INFORMATION AREA ON THE LEFT DISPLAY. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 17 WORKING SCREEN. THE RED LAMP AND THE AUDIBLE ALARM WILL OPERATE WHENEVER THE BOOM TIP HEIGHT EXCEEDS 75 FEET. THE MESSAGE MAX HEIGHT WILL APPEAR IN THE INFORMATION AREA ON THE LEFT DISPLAY. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 18: Canceling Alarms

    4. MOVE THE CURSOR TO POINT TO THE NEXT ALARM TO BE CANCELED. 5. WHEN ALL THE CHOSEN ALARMS ARE CANCELED PRESS SELECT TO RETURN TO THE WORKING SCREEN. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 19: Periodic Inspections

    OUT CIRCUITS. TAKE CARE THAT THE CRANE IS NOT PUT INTO AN ACTUAL TWO-BLOCK CONDITION INADVERTENTLY. DO NOT OPERATE THE CRANE UNDER THE ABOVE CONDITIONS. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 20: System Checks

    OBVIOUS SIGNS OF WEAR AND TEAR AND INSPECTION OF MECHANICAL PARTS SUCH AS REELING DRUMS, HOIST ROPE TENSIOMETERS AND ANTI TWO-BLOCK SWITCHES. GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107- ...
  • Page 21 GREER COMPANY Crane Systems Crane Systems Crane Systems Crane Systems GREER COMPANY 1918 East Glenwood Place, Santa Ana, CA 92705 Tel: 714) 259-9702 Fax: 714) 259-7626 PN W414107-  MicroGuard 414 System Lattice Boom Cranes Horizontal Display Clyde M4190 Barge Mount OPERATOR'S MANUAL...

Table of Contents