Wonderfire Overture 2 BR265 Installer's Manual

Inset decorative gas fire

Advertisement

I
N
S
T
A
L
L
E
R
G
U
I
D
E
For
MODEL BR265
OVERTURE
Inset Decorative Gas Fire
(GC No. 32-032-16)
Please keep in a safe place for future reference
600B 389/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Overture 2 BR265 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Wonderfire Overture 2 BR265

  • Page 1 MODEL BR265 OVERTURE Inset Decorative Gas Fire (GC No. 32-032-16) Please keep in a safe place for future reference 600B 389/03...
  • Page 2 (GB) and the Republic of Ireland (IE) only. This Installer Guide gives sufficient details to enable the appliance to be installed and maintained. If further information is required, our Wonderfire service department will be pleased to help. Please phone us on 0121 386 6203.
  • Page 3: Appliance Data

    1. APPLIANCE DATA This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which are man-made vitreous silicate fibres. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract. Consequently, it makes sense to take care when handling these articles to ensure that the release of dust is kept to a minimum. To ensure that the release of fibres from these RCF articles is kept to a minimum, during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot accumulated in and around the fire before and after working on the fire.
  • Page 4 2.5 In the United Kingdom (GB) no special ventilation 2.11.2 To a fireplace that has a precast concrete or clay flue bricks or vents are required in the room for this appliance. block system conforming to BS1289. The appliance is suitable In the Republic of Ireland (IE), permanent ventilation must for installations conforming to older versions of BS1289 as comply with the regulations currently in force.
  • Page 5: Preliminary Checks

    2.12 The appliance must be mounted behind a non- 2.13 The flue must not be used for any other appliance or combustible hearth with minimum dimensions as figure 5. application. (n.b conglomerate marble hearths are considered as non- combustible). The appliance can be fitted to a purpose made 2.14 If the fireplace opening is of underfloor draught type, it proprietary class “O”...
  • Page 6: Gas Supply Connection

    4. GAS SUPPLY CONNECTION 8mm Bundy or semi-rigid tubing must be used to connect the provided for an 8mm pipe inlet connection to the elbow at the appliance to the gas supply. Centre the appliance in the bottom front of the appliance. The elbow can be rotated to fireplace opening taking care not to scratch or damage the allow a connection from any direction.
  • Page 7: Installation To Fireplace

    6. INSTALLATION TO FIREPLACE Cable Retention Preliminary Burner Checks Cables and eyebolts are Some burner operations can be checked at this stage. supplied for the Checking now will mean that less disassembly will be required retention of the it any problems are found. appliance.
  • Page 8 7. CERAMICS INSTALLATION 7.1 Make sure that the 7.3.2 Place four of the tray trim is fitted over the remaining coals in the four front edge of the burner valleys of the front coal. tray and that it is pushed Place the left side coal so fully down.
  • Page 9: Full Operating Checks

    This monitoring system must not be adjusted, bypassed or put out of operation. This monitoring system, or any of its parts, must only be exchanged using Wonderfire Authorised parts.
  • Page 10: Final Review

    9. FINAL REVIEW Hand these instructions and the owner’s guide to the Advise the customer that the front surround, firebox and • • customer. ceramic pieces can be cleaned as described in the owner’s Advise the customer how to operate the appliance. guide and that the coal pieces must be replaced as •...
  • Page 11: Servicing & Parts Replacement

    10. SERVICING & PARTS REPLACEMENT Always turn off the gas supply before commencing any servicing. (The inlet elbow for this appliance incorporates an isolating valve). • This product uses fuel effect pieces, burner compartment walls and gaskets containing Refractory Ceramic Fibres (RCF), which are •...
  • Page 12 10.4 To Remove The Gas Tap/F.S.D. 10.6.5 Clean and grease the plug lightly with suitable grease. Do not apply excessive grease. Particularly, make sure 10.4.1 Remove the burner unit - See section 10.2. that the gas ports in the tap are not restricted by grease. 10.4.2 Disconnect the electrode lead from tab underneath 10.6.6...
  • Page 13: Short List Of Spares

    Pilot unit For Propane Appliances 544929 Burner plaque & gasket set 569439 Ceramic rear wall 9770081 Front coal 9770074 Rear base coal 9770082 Pack of loose coals 9780037 Dust cage 567619 MANUFACTURED BY WONDERFIRE, WOOD LANE, ERDINGTON, BIRMINGHAM, B24 9QP...